Assessment of fluid responsiveness (FR) is to detect whether patient could benefit from fluid therapy. Mini fluid challenge has been widely used in clinical practice to prevent patients from volume overload. In clinical practice, 100 mL or 250 mL have been used most frequently and FR was defined as an increase in CO greater than 10% as much as the changes in CO after infusion of 500 mL. While using a half of volume infusion and assessed by the traditional standard of FR, this might misclassify more patients as nonresponders. In that it is imperative to test the predictive ability of mini fluid and find out the threshold of cutoff value. Meanwhile, in almost mini-FC, cardiac output were measured by echocardiography(VTi) and pulse contour,None of the studies conducted cardiac output (CO)measurement by gold standard method of thermodilution by pulmonary artery catheter (PAC). The correlation between new generated CO measurements and PAC varies in different studies as well. It is imperative to investigate the reliability of mini-FC to predicting fluid responsiveness(FR).The investigator's study is to detect the predictive minimal volume using thermodilution by PAC in septic shock patient.
Fluid therapy is the cornerstone of septic resuscitation. In recent decade, a restrictive fluid strategy has been applied to shock resuscitation for fewer complications and shorter hospital stays compared with a liberal fluid strategy. Therefore, it is a reasonable step to assess the patient's response to fluid infusion to avoid excessive fluid administration.Mini-fluid challenge allows the selection of fluid responders by inducible changes of hemodynamic parameters after changing the preload gaining popularity. The mini fluid challenge was firstly described by Muller et al. in 2011. They found an infusion of 100 mL colloid over 1 minute and the assessment by cardiac output using velocity time integral (VTi) at the aortic outflow tract could predict fluid responsiveness (FR). Since then, a total of seven investigations have been published. Although a mini-fluid challenge may help the decision-making process of fluid management, the investigation results differed from each other, especially in minimal volume and cut off value of hemodynamic parameters change. Meanwhile, we noticed that when measuring CO, the method of thermodilution by pulmonary artery catheter (PAC), which is the gold standard of CO measurement, was not used in these studies. Furthermore, the majority participants of the studies were perioperative patients in a stable hemodynamic state.Therefore, there are two question needed to be answered:what is the minimal infusion volume in effectively predicting fluid responsiveness, and whether mini-volume can perform a real change in septic shock patients. Thus, it is necessary to explore the minimal volume in fluid challenge by PAC and test its reliability in detecting responders (R) and nonresponders (NR).
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
50
Pulmonary artery catheter insertion is prepared before fluid challenge. Baseline hemodynamic value and each time after 5 sequential intravenous boluses of 100 mL colloid are recorded.
Li Weng
Beijing, Beijing Municipality, China
RECRUITINGCardiac output
Cardiac output measured by therm-dilution of pulmonary artery catheter. An increase in cardiac output(CO) greater than 10% after a volume expansion of 500 mL is defined as fluid responsiveness(FR).
Time frame: Baseline and immediately after each bolus of 100 mL colloid, average 3 minutes
Oxygen saturation
Oxygen saturation can be obtained directly from blood gas include which reflects extraction of oxygen and assess whether CO is sufficient enough to meet patient's enough.
Time frame: Baseline and immediately after each bolus of 100 mL colloid, average 3 minutes
Carbon dioxide partial pressure
PCO2 can be obtained directly from blood gas. It is considered as alternative markers of tissue hypoperfusion and attempted to be used to guide treatment for shock.
Time frame: Baseline and immediately after each bolus of 100 mL colloid, average 3 minutes
Hemoglobin
Hemoglobin will be diluted during fluid challenge and it is also an important index to guide fluid resuscitation by improving extraction of oxygen and optimizing oxygen delivery.
Time frame: Baseline and immediately after each bolus of 100 mL colloid, average 3 minutes
Heart rate
Heart rate is monitored to assess the effect of the fluid challenge
Time frame: Baseline and immediately after each bolus of 100 mL colloid, average 1 minutes
Mean arterial pressure
Mean arterial pressure is monitored to assess the effect of the fluid challenge
Time frame: Baseline and immediately after each bolus of 100 mL colloid, average 1 minutes
Central venous pressure
Central venous pressure is monitored to assess the preload status and effect of the fluid challenge
Time frame: Baseline and immediately after each bolus of 100 mL colloid, average 1 minutes