To establish the safety and effectiveness of the DragonFly transcatheter mitral valve repair system in symptomatic patients with moderate to severe and severe mitral regurgitation who have been determined to be at an high risk of mortality with mitral valve surgery by the cardiac surgeon with concurrence by the local Heart Team
The subjects with moderate-to-severe (3+) and severe (4+) mitral valve regurgitation (MR) at high or prohibitive surgical risk will be evaluated by the study sites, and study eligibility confirmed by the echocardiographic core laboratory and eligibility committee. Those qualifying will then be treated with Dragonfly transcatheter mitral valve repair system after signing the informed consent. The follow-up will be conducted at discharge, 30 days, 6 months and 12 months after the operation. The primary endpoints are the incidence of major adverse events (MAE) at 30 days, and acute procedural success. Acute procedural success is defined as placement of one or more Dragonfly devices on the mitral valve with reduction of MR to 2+ or less. The secondary endpoints include all-cause mortality, cardiovascular mortality, incidence of serious adverse event, cardiovascular rehospitalization, NYHA functional class, mitral valve hemodynamics, acute technical success rate and device success rate at 6 months. Acute technical success is defined as no procedural mortality, successful in access, delivery, and retrieval of the device delivery system, and no emergency surgery or reintervention related to the device or access procedure in the catheterization laboratory. Device success is defined as no procedural mortality, proper delivery and deployment of the device, no unplanned surgical or interventional procedures related to the device, no specific device-related technical failure and or complications, function improvement of MR without significant stenosis (MR ≤ 2+) and without associated hemolysis or thrombogenesis.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
20
With transesophageal echocardiographic guidance,implanting clip using Dragonfly mitral valve repair system
The Second Affiliated Hospital of Zhejiang University
Hangzhou, Zhejiang, China
Incidence of acute procedural success
The acute procedural success is defined as successful Dragonfly implantation, and residual MR of 2+ or less at discharge. An echocardiogram at 30 days can be accepted if the discharge image was not available or hard to interpret. A death before discharge or a re-operation of mitral valve prior to 30 days is defined as acute procedure failure
Time frame: 1 month
Incidence of major adverse event (MAE) at 30 days
Major adverse event is defined as one of the following components: death, myocardial infarction (MI), stroke, renal failure requiring dialysis, and cardiac surgery for Dragonfly device failure.
Time frame: 1 month
All-cause mortality
Death from any cause
Time frame: 6 months
Cardiovascular mortality
Death from cardiac causes
Time frame: 6 months
Incidence of serious adverse event (SAE)
If the adverse event meets any of the criteria below, it is regarded as a serious adverse event (SAE): 1) results in death; 2) is life threatening, results in illness or injury; 3) requires inpatient hospitalization or prolongation of existing hospitalization; 4) results in a persistent or significant disability/incapacity; 5) results in a congenital anomaly/birth defect, fetal death, fetal distress; 6) results in medical or surgical intervention to prevent permanent impairment to body structure or a body function; 7) an important medical event that may not result in death, be life-threatening, or require hospitalization but may be considered serious when, based upon appropriate medical judgment, may jeopardize the patient or subject and/or may require intervention to prevent one of the outcomes listed in this definition.
Time frame: 6 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
NYHA
NYHA functional class
Time frame: 6 months
Technical success
must meet all of the following items: 1) no procedural mortality; and 2) successful in access, delivery, and retrieval of the device delivery system; and 3) no emergency surgery or reintervention related to the device or access procedure.
Time frame: Immediately after procedure
Device success
must meet all of the following items:1) No procedural mortality; 2) Proper delivery and deployment of the device; 3) No unplanned surgical or interventional procedures related to the device; 4) No specific device-related technical failure or complication. 5) Improvement of MR without significant stenosis (MR ≤ 2+) without associated hemolysis or thrombogenesis.