Rapid maxillary expansion (RME) is a commonly used orthodontic treatment in patients with maxillary constriction to provide skeletal expansion, correct posterior crossbite and resolve naso-respiratory problems by reducing oral respiration.The aim of this randomized controlled trial was to evaluate the effects of tooth-borne, tooth tissue-borne and bone-borne RME appliances on sleep quality with polygraphy. The null hypothesis was that there is no difference for the sleep quality between the appliances.
Introduction. The aim of this 3-arm randomized controlled trial (RCT) was to evaluate the effects of tooth tissue-borne (KBME), tooth-borne (Hyrax), and bone-borne (MIDME) rapid maxillary expansion (RME) appliances on sleep quality with polygraphy. Methods. This study was designed in parallel with an allocation ratio of 1:1:1. 46 patients with narrow maxilla and OSAS were included in this study and randomly assigned to three groups: tooth tissue-borne, tooth-borne and bone-borne expanders. Participants were congregated from the Department of Orthodontics, Faculty of Dentistry, Izmir Katip Celebi University, Turkey. In all groups, the expansion appliance was activated one-quarter turn twice a day until the desired suture opening was achieved. The primary outcome of this study was the correction of posterior crossbite. Secondary outcomes included polygraphic assessment of sleep parameters. Each subject participated in 1 overnight sleep test with polygraphy before the expansion (T0) and after a 3-month retention phase of treatment (T1). According to the results of polygraphy, 7 parameters; (apnea hypopnea index (AHI), number of apnea and hypopnea, desaturation index, lowest desaturation, average saturation, supin AHI) were examined to evaluate the changes in sleep scores. Kruskal-Wallis analysis and Dunn-Bonferroni test were used for inter-group comparisons and Wilcoxon analysis was used for intra-group evalaution. P\<0.05 was accepted statistically significant. Computer-generated randomization was used with group allocation concealed using opaque, sealed envelopes. The outcome assessor was blinded to group assignment. The outcome assessor was blinded; however, it was not feasible to blind either operator or patients.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
46
The patients were treated with KBME, Hyrax and MIDME maxillary expansion appliances, respectively. All expansion appliances containing a Hyrax expansion screw positioned parallel to the second premolars and were used to correct the posterior crossbite. In the MIDME group, two mini-screws with a diameter of 1.6 mm and a length of 10 mm are located on the right and left sides between the roots of the 2nd premolar and 1st molar teeth with 60-70° angle. KBME and Hyrax expansion appliances were cemented with glass ionomer cement and MIDME was cemented with using the light-cured composite. Same protocol was applied to all patients during RME treatment. Expansion screws in all groups were activated by two turns a day.
Correction of posterior crossbite
The palatal cusps of the maxillary posterior teeth approximated the lingual cusps of the mandibular posterior teeth.
Time frame: After active expansion (up to 3 weeks). The evaluation of the result has been made by the physician with intraoral clinical examination.
Polygraphic assessment of sleep parameters
Changes in apnea hypopnea index (AHI)
Time frame: After 3 months treatment retention period
Polygraphic assessment of sleep parameters
Changes in number of apnea and hypopnea
Time frame: After 3 months treatment retention period
Polygraphic assessment of sleep parameters
Changes in number of hypopnea
Time frame: After 3 months treatment retention period
Polygraphic assessment of sleep parameters
Changes in desaturation index
Time frame: After 3 months treatment retention period
Polygraphic assessment of sleep parameters
Changes in lowest desaturation
Time frame: After 3 months treatment retention period
Polygraphic assessment of sleep parameters
Changes in average saturation
Time frame: After 3 months treatment retention period
Polygraphic assessment of sleep parameters
Changes in the value of Supin AHI
Time frame: After 3 months treatment retention period
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.