Scleral lenses have emerged as an efficacious treatment option for various types of intractable ocular surface diseases with many advantageous results. The purpose of this study was to report the efficacy and safety of the LK scleral lenses and determine their suitability in Asian patients with intractable ocular surface diseases. Subjects with intractable ocular surface diseases are enrolled to fit LK scleral lenses for 12 weeks for a prospective study. Evaluations are performed at 1, 4, 8 and 12 weeks. General patient demographics and medical history, visual acuities, thorough ophthalmic evaluation, ocular surface disease index and National Eye Institute 25-Item Visual Function Questionnaire are collected for each patient.
To date, there are several commercially manufactured scleral lenses of different designs and sizes, all of which have been proven to be clinically beneficial in a wide spectrum of diseases. Especially in the management of intractable ocular surface diseases, scleral lenses with large diameters are commonly used so that the lens entirely rests on the sclera with sufficient tear reservoir. PROSE devices (Boston Foundation for Sight, Needham, MA), one of the first and representative scleral lenses shown to have long-term clinical benefits for complex corneal diseases, have large diameters of 17.5 to 23.0 mm. However, in Republic of Korea, only scleral lenses with small diameters are currently available. SoClearⓇ and OnefitⓇ scleral lenses, two of the most commonly used scleral lenses in Republic of Korea, possess diameters ranging from 14.1 to 15.5 mm and 13.3 to 15.0 mm, respectively, and are not actually fully scleral but more of a corneoscleral type lenses. Furthermore, Asians have smaller palpebral fissures with tighter eyelids than the Western population, which may restrict patients' tolerability of wearing a large scleral lens and limit its clinical benefits. Therefore, a more suitable scleral lens for Asians with larger diameter is required. Accordingly, this study investigates the efficacy and safety of the LK scleral lens (Lucid Korea LTD, Seoul, Republic of Korea), which has been newly manufactured to have larger diameters than currently available commercial lenses, and determines their suitability in Asian patients with intractable ocular surface diseases.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
16
LK scleral lens fitting and application were done for 12 weeks.
Change of visual improvement after wearing the LK scleral lens
Best corrected visual acuity is measured. Snellen visual acuity is converted to log of the Minimum Angle of Resolution for assessment.
Time frame: Change from baseline best corrected visual acuity at week 1
Change of visual improvement after wearing the LK scleral lens
Best corrected visual acuity is measured. Snellen visual acuity is converted to log of the Minimum Angle of Resolution for assessment.
Time frame: Change from baseline best corrected visual acuity at week 4
Change of visual improvement after wearing the LK scleral lens
Best corrected visual acuity is measured. Snellen visual acuity is converted to log of the Minimum Angle of Resolution for assessment.
Time frame: Change from baseline best corrected visual acuity at week 8
Change of visual improvement after wearing the LK scleral lens
Best corrected visual acuity is measured. Snellen visual acuity is converted to log of the Minimum Angle of Resolution for assessment.
Time frame: Change from baseline best corrected visual acuity at week 12
Change of ocular surface state after wearing the LK scleral lens
0.5% Fluorescein application to the ocular surface and observation under blue light exhibits ocular surface epithelial erosions that are associated with chronic dry eyes and irregular tear film status. Grading is performed through Oxford Grading which ranges from 0 = none to 5 = severe.
Time frame: Change from baseline ocular surface state at week 1
Change of ocular surface state after wearing the LK scleral lens
0.5% Fluorescein application to the ocular surface and observation under blue light exhibits ocular surface epithelial erosions that are associated with chronic dry eyes and irregular tear film status. Grading is performed through Oxford Grading which ranges from 0 = none to 5 = severe.
Time frame: Change from baseline ocular surface state at week 4
Change of ocular surface state after wearing the LK scleral lens
0.5% Fluorescein application to the ocular surface and observation under blue light exhibits ocular surface epithelial erosions that are associated with chronic dry eyes and irregular tear film status. Grading is performed through Oxford Grading which ranges from 0 = none to 5 = severe.
Time frame: Change from baseline ocular surface state at week 8
Change of ocular surface state after wearing the LK scleral lens
0.5% Fluorescein application to the ocular surface and observation under blue light exhibits ocular surface epithelial erosions that are associated with chronic dry eyes and irregular tear film status. Grading is performed through Oxford Grading which ranges from 0 = none to 5 = severe.
Time frame: Change from baseline ocular surface state at week 12
Change of subjective ocular surface discomfort after wearing the LK scleral lens
25-Item Visual Function Questionnaire scores is a validated self-reporting dry eye symptom questionnaires. The scores are graded from 0 = no symptoms to 100 = all symptoms with the most severity.
Time frame: Change from baseline 25-Item Visual Function Questionnaire scores at week 1
Change of subjective ocular surface discomfort after wearing the LK scleral lens
25-Item Visual Function Questionnaire scores is a validated self-reporting dry eye symptom questionnaires. The scores are graded from 0 = no symptoms to 100 = all symptoms with the most severity.
Time frame: Change from baseline 25-Item Visual Function Questionnaire scores at week 4
Change of subjective ocular surface discomfort after wearing the LK scleral lens
25-Item Visual Function Questionnaire scores is a validated self-reporting dry eye symptom questionnaires. The scores are graded from 0 = no symptoms to 100 = all symptoms with the most severity.
Time frame: Change from baseline 25-Item Visual Function Questionnaire scores at week 8
Change of subjective ocular surface discomfort after wearing the LK scleral lens
25-Item Visual Function Questionnaire scores is a validated self-reporting dry eye symptom questionnaires. The scores are graded from 0 = no symptoms to 100 = all symptoms with the most severity.
Time frame: Change from baseline 25-Item Visual Function Questionnaire scores at week 12
Change of subjective ocular surface discomfort after wearing the LK scleral lens
Ocular surface disease index is validated self-reporting dry eye symptom questionnaires. The scores are graded from 0 = no symptoms to 48 = all symptoms with the most severity.
Time frame: Change from baseline ocular surface disease index at week 1
Change of subjective ocular surface discomfort after wearing the LK scleral lens
Ocular surface disease index is validated self-reporting dry eye symptom questionnaires. The scores are graded from 0 = no symptoms to 48 = all symptoms with the most severity.
Time frame: Change from baseline ocular surface disease index at week 4
Change of subjective ocular surface discomfort after wearing the LK scleral lens
Ocular surface disease index is validated self-reporting dry eye symptom questionnaires. The scores are graded from 0 = no symptoms to 48 = all symptoms with the most severity.
Time frame: Change from baseline ocular surface disease index at week 8
Change of subjective ocular surface discomfort after wearing the LK scleral lens
Ocular surface disease index is validated self-reporting dry eye symptom questionnaires. The scores are graded from 0 = no symptoms to 48 = all symptoms with the most severity.
Time frame: Change from baseline ocular surface disease index at week 12
Adverse effects after wearing the LK scleral lens
Scleral lenses can cause endothelial cell density decrease and corneal edema. Endothelial cell density was assessed using a noncontact specular microscope, while corneal edema whereabouts was evaluating corneal thickness using ultrasound pachymetry.
Time frame: Week 12
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.