The Neodent® Zirconia Implant is designed for the treatment of oral endosteal implantation for the functional and aesthetic rehabilitation, allowing for treatment of patients with different bone qualities. The objective of the study is to assess the success and survival rates of implantable devices of the Zirconia System, in order to confirm the long-term safety and clinical performance of implants and abutments of the Zirconia System in daily dental practice setting. Devices will be used according to standard routine in daily practice, according to manufacturer indications in the IFU. Patients will be followed for 36 months after implant placement.
The study protocol was reviewed and approved by an Ethics Committee (CE) in Brazil. The sample will be prospectively and consecutively selected and will consist of patients who are 18 years of age or older, who are in need of and who qualify for single dental implants placement in the posterior maxilla region with Neodent® Zirconia. Informed consent in writing will be obtained from each patient participating in the study prior to any study related procedure. As this study will be analyzed descriptively, sample size calculation was not performed. To generate reliable results, a total number of 30 implants was assumed to be sufficient. Estimating a rate of 1 implant per patient and a drop-out rate of 15%, a sample size of 36 patients resulting in an estimated number of 36 implants is thought to be sufficient to allow for a descriptive analysis of clinical outcome data up to 36 months after implant placement. Treatment provided to the subjects will be the responsibility of an appropriately qualified dental practitioner to provide the relevant patient care under clinical study conditions. Zirconia Implants will be placed under local anesthesia and with adequate bone bed preparation in posterior maxilla region. More than one implant can be placed in the same patient, as long as the subject presents natural teeth adjacent to the implant site. Immediately after implant placement, the final placement torque will be registered. The immediate loading will be applied within 48 hours with the insertion of a provisional prosthesis made from intraoral scanning or scanning of dental casts obtained by conventional impression. The insertion torque shall reach at least 35 N.cm and the subject must have physiologic occlusion to immediate loading. If the patient does not reach the minimum torque (35 N.cm), the patient will be followed until the study end but will not be considered to final statistic or, a different implant line would be placed and the study termination form will be filled. The principal investigator will choose how to procedure in this situation. The selection of the prosthetic component shall be conducted according to the need of each subject and to the manufacturer's instructions (IFU). The final prosthesis will be placed 2 months after implant loading. Data concerning the studied variables will be collected following the procedures and assessments plan by fulfilling the Case Report Form (CRF), in the following stages: screening (First visit); TP - Implant(s) placement and impression/scanning for temporary prosthesis preparation; T0 - Implant(s) loading (up to 48h after placement); TF - Final prosthesis placement (2 months ± 1 week after loading); T6, T12, T24, T36 - 6, 12, 24 e 36 ± 1 month, respectively, after loading. Standardized digital periapical radiographs will be obtained in a usual daily practice frequency, as determined by the investigator: at pre-operative, to assess the ridge height and width of the supporting bone and locate major anatomical features; in post-surgery (TP) and in T0, TF, T6, T12, T24 and T36 to verify prosthesis adaptation and osseointegration. Computed tomography scans will be obtained from the region of interest prior to surgery, for the selection of the implant to be inserted.
Study Type
OBSERVATIONAL
Enrollment
36
Dental Implants will be used according to standard routine in daily practice, according to all indications as specified by the manufacturer in the IFU (informations for use).
Instituto Latino Americano de Pesquisa e Ensino Odontológico (ILAPEO)
Curitiba, Paraná, Brazil
Implant survival rate
Implant survival will be defined as no loss of the implant.
Time frame: 36 months after implant placement
Implant success rate
Evaluation of implant success will be assessed based on the criteria proposed by Buser et al. (1990).
Time frame: 36 months after implant placement
Implant survival rate
Implant survival will be defined as no loss of the implant.
Time frame: 6 months after implant placement
Implant success rate
Evaluation of implant success will be assessed based on the criteria proposed by Buser et al. (1990).
Time frame: 6 months after implant placement
Prosthetic survival rate
Prosthetic survival will be assessed as the final prosthesis remaining in situ, irrespective of its condition.
Time frame: 36 months after implant placement
Prosthetic success rate
Success will be defined as the prosthesis that remained unchanged and did not require any intervention, except routine occlusal adjustments, during the entire observational period
Time frame: 36 months after implant placement
Patient satisfaction: questionnaire
OHIP-14 questionnaire will be used to assess Oral Health Related Quality of Life (OHRQoL), as a measure of patient satisfaction with treatment. Patients will be asked how frequently they have been experiencing the problems assessed by the questionnaire. Small values mean a better quality of life.
Time frame: At screening visit, after the temporary prosthesis period and 6, 12, 24 and 36 months after implant placement
Clinician satisfaction: questionnaire
The assessment will be performed by means of a questionnaire using a visual analog scale (VAS) in the form of a 10 cm horizontal line, where 0 (left end) indicates minimum satisfaction and 10 (right end) indicates maximum satisfaction. The clinician will be instructed to mark the position considered to best represent their degree of general satisfaction with patient treatment. The score will be measured in centimeters from the left end of the line to the marked point.
Time frame: At implant placement, implant loading and 6, 12, 24 and 36 months after implant placement
Rate of adverse events related to the implant, prosthesis, surgery and oral health
Determined by inquiring with the patient and clinical evaluation.
Time frame: At implant placement, implant loading, final prosthesis placement and 6, 12, 24 and 36 months after implant placement
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.