The objectives if this study was to evaluate the efficacy of 3 different rectangular archwires in the correction of the curve of Spee (COS), to record the time needed to level excessive COS in the mandibular arch using the 3 archwire sizes, to investigate the changes in intercanine and intermolar widths and arch length during leveling, to measure the arterio-posterior and vertical movement for the lower incisors and lower molars, to record pulpal blood flow and to detect the root resorption in the lower anterior teeth associated with leveling excessive COS using the 3 different archwires.
Fifty one subjects with an excessive COS were included in this study. The subjects will be randomly divided into three groups; Group one (17 patients): leveling of COS using 0.017X0.025-inch stainless steel archwire. Group two (17 patients): leveling of COS using 0.019X0.025-inch stainless steel archwire. Group three (17 patients): leveling of COS using 0.021X0.025-inch Titanium molybdenum archwire. In the three groups, a 5mm depth reverse COS will be inserted. Records consisted of lateral cephalograms (pre-treatment, at T0 and post-treatment), peri-apical radiographs (at T0 and at T5), study casts (pre-treatment and at each time point during the tudy). Patients will be followed up on monthly visits without removing leveling archwires where alginate impressions were taken for the lower arch. Pain scores during the first week of leveling will be recorded using visual analogue scale (VAS).The amount of COS correction in mm, changes in intercanine in mm, intermolar and arch length in mm, pain scores and lower incisors root resorptions in mm will be measured.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
51
Leveling curve of Sppe using 0.017X0.025 SS archwire
Leveling curve of Sppe using 0.019X0.025 Stainless steel archwire
Leveling curve of Sppe using 0.019X0.025 B-Titanium archwire
Jordan University of Science and Technology
Irbid, Jordan
Curve of Spee depth changes during leveling
The change in Curve of Spee in millimetres
Time frame: 4 to 6 months
Pain perception
A10-point visual analogue scale of 10 cm length where 0 indicate no pain and 10 indicate intolerable pain
Time frame: one week
Root Resorption
change in root length in millimeters
Time frame: 6 months
Pulpal blood flow
Change in blood flow using laser flowmetry
Time frame: one month
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.