In this experiment the investigators would like to assess if papain induces an itch sensation comparable to the itch sensation induced by cowhage and to confirm that the mechanism of action of papain follows the non-histaminergic pathway.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
BASIC_SCIENCE
Masking
SINGLE
Enrollment
20
Four of the areas will be treated with doxepin for 1 hour and 30 minutes (with a patch to deposit 1.2 grams of cream). Each patch will be covered with Tegaderm I.V., an occlusive, adhesive dressing (3M), for at least 1½ hours
Papain will be applied by 1 SPT prick thought the skin
Histamine will be applied by 1 SPT prick thought the skin
Aalborg University
Aalborg, North Denmark, Denmark
Superficial blood perfusion
Superficial blood perfusion is measured by a Speckle contrast imager (FLPI, Moor Instruments, England).
Time frame: 15 minutes
Measuring itch intensity by computerized Visual Analog Scale Scoring
The subjects will rate the sensation of itch on a 100 mm VAS scale ranging from 0 to 100 where 0 indicates "no itch" and 100 indicates "worst itch imaginable" and similarly for sensations of stinging/pricking and burning, both of which are frequently associated with the sensation of itch.
Time frame: 15 minutes
Measuring pain intensity by computerized Visual Analog Scale Scoring
The subjects will rate the sensation of pain on a 100 mm VAS scale ranging from 0 to 100 where 0 indicates "no pain" and 100 indicates "worst pain imaginable".
Time frame: 15 minutes
Measuring Alloknesis
Alloknesis is measured by using mildly pruritic, non-painful von Frey nylon filaments of a predetermined intensity (generally 5-30 milliNewton of force). This stimulator is applied 0.5 cm outside the area of itch provocation.
Time frame: 15 minutes
Measurement of Cold Detection Thresholds (CDT)
The tests for thermal sensation will all be conducted using a PATHWAY ATS (Medoc Ltd, Israel) thermal sensory testing device. A thermode stimulator of 3x3 cm will be placed on the treated/placebo areas and kept in place by means of Velcro tape. During the first 8 seconds, the temperature decreases 1°C per second from a starting temperature of 32°C until the subject perceives a temperature change (cold sensation) and presses a button that will terminate the measurement and return the temperature to baseline at a rate of 5°C /s. A cut-off temperature of 0°C will be used.
Time frame: 15 minutes
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Cowhage spicules are 1-2 mm in length and have diameter of 1-3 µm at their tip. 30-35 spicules are gently rubbed into a 1 cm diameter skin area.
Measurement of Cold PainThresholds (CPT)
The tests for thermal sensation will all be conducted using a PATHWAY ATS (Medoc Ltd, Israel) thermal sensory testing device. A thermode stimulator of 3x3 cm will be placed on the treated/placebo areas and kept in place by means of Velcro tape. During the first 8 seconds, the temperature decreases 1°C per second from a starting temperature of 32°C until the subject perceives a temperature change (cold sensation) and presses a button that will terminate the measurement and return the temperature to baseline at a rate of 5°C /s. A cut-off temperature of 0°C will be used.
Time frame: 15 minutes
Measurement of Heat Pain Thresholds (HPT)
The tests for thermal sensation will all be performed using a PATHWAY ATS (Medoc Ltd, Israel) thermal sensory testing device. A thermode stimulator of 3x3 cm will be placed on the treated/placebo areas and kept in place by means of Velcro tape. During the first 8 seconds, the temperature raises 1°C per second from a starting temperature of 32°C until the subject detects a painful sensation and presses a button that will terminate the measurement and return the temperature to baseline at a rate of 5°C /s. A cut-off temperature of 52°C will be used.
Time frame: 15 minutes
Measurement of Warm Detection Thresholds (WDT)
The tests for thermal sensation will all be performed using a PATHWAY ATS (Medoc Ltd, Israel) thermal sensory testing device. A thermode stimulator of 3x3 cm will be placed on the treated/placebo areas and kept in place by means of Velcro tape. During the first 8 seconds, the temperature raises 1°C per second from a starting temperature of 32°C until the subject detects a painful sensation and presses a button that will terminate the measurement and return the temperature to baseline at a rate of 5°C /s. A cut-off temperature of 52°C will be used.
Time frame: 15 minutes
Measurement of Pain to Supra-threshold Heat Stimuli
The tests will be conducted by using a PATHWAY ATS (Medoc Ltd, Israel) thermal sensory testing device. A thermode stimulator of 3x3 cm will be placed on the treated/placebo areas and kept in place by means of Velcro tape. The subjects will have to rate the pain to two suprathreshold heat pain stimuli (starting and ending at 32°C with an increase and decrease of 5°C and 3 s plateau at 50°C).
Time frame: 15 minutes
Measurement of Mechanical Pain Thresholds (MPT)
This test is conducted using a pin-prick set (Aalborg University, Aalborg). This test is conducted using a pin-prick set (Aalborg University, Aalborg).easurement of Mechanical Pain Thresholds (MPT)
Time frame: 15 minutes
Measurement of Mechanical Pain Sensitivity (MPS)
This test is conducted using a pin-prick set (Aalborg University, Aalborg).
Time frame: 15 minutes
Touch Pleasantness (TP)
Pleasant touch sensation measured using astandardized sensory brush (SENSELab Brush-05, Somedic AB, Hörby, Sweden) exerting a force of 200 to 400 mN.
Time frame: 15 minutes