This study aims to investigate the safety and efficacy of transcatheter exclusion of atrial septal aneurysm (ASA) via transseptal perforation in patients with ASA.
Atrial septal aneurysm (ASA) has been considered a potential cardiac source of embolism, and its prevalence is about 1%. In adult patients with stroke and normal carotid arteries, ASA is an important predictor of recurrent stroke. The most common abnormalities associated are interatrial shunts, that is, a patent foramen ovale (PFO) or an atrial septal defect (ASD). For large ASA with interatrial shunt, it is difficult to cover ASA with conventional devices, which might result in unstability of occluders and related complications . For isolated ASA with high risk, thrombus and emboli have been reported and anticoagulation has been used empirically. In addition, the left atrial septal pouch can be considered as a special subtype of atrial septal aneurysm, in which thrombus might arise from the cavity of the pouch. Pervious researches have noted that left atrial septal pouch was a site of origin of thrombus formation and a source of embolism, and it was associated with cryptogenic stroke. For patients with ASA, we hypothesizes that transcatheter reconstruction of atrial septum might be achieved with PFO occluder through transseptal perforation. The aim of this study is to investigate the safety and efficacy of transcatheter exclusion of ASA via transseptal perforation. This study will enroll subjects with ASA (including left atrial septal pouch), and enrollment will be divided into three phases. Phase 1: large ASA patients with interatrial communication (ASD or PFO). A maximum of 30 patients is reached. Phase 2: ASA patients with intact septum and high risk of cryptogenic stroke. A maximum of 20 patients is reached. Phase 3: left atrial septal pouch with high risk of cryptogenic stroke. A maximum of 20 patients is reached.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
70
Through transseptal perforation, transcatheter reconstruction of atrial septum was achieved with PFO occluder to cover the whole ASA. Device: Cardi-O-Fix™ patent foramen ovale occluder (Starway Medical Technology, Inc. Beijing, CN)
Yan Chaowu
Beijing, Beijing Municipality, China
RECRUITINGYan Chaowu
Beijing, Beijing Municipality, China
RECRUITINGNumber of subjects with effective exclusion of ASA
Assessment of ASA exclusion by echocardiography/MSCT during follow-up. Effective exclusion of ASA was defined as complete coverage of whole ASA.
Time frame: 12 months
Procedural or device complications
Procedural or device complications during follow-up
Time frame: 12 months
Adverse event rates for all subjects
including migraine (severity, frequency and duration with or without aura), TIA, ischemic stroke or systemic embolism.
Time frame: 12 months