This study investigates the test-retest reliability of the lung diffusing capacity for nitric oxide in healthy individuals during exercise.
The aim of this study of to evaluate the test-retest reliability of single-breath lung diffusing capacity measurements for nitric oxide (DLNO) in healthy individuals during light and moderate intensity cycling exercise. Healthy subjects will perform repeated single-breath DLNO measurements during light (i.e., at 50% of the first ventilatory threshold) and moderate intensity exercise (i.e., 80% of the first ventilatory threshold) on a stationary cycle ergometer.
Study Type
OBSERVATIONAL
Enrollment
17
University of Zurich and University Hospital of Zurich
Zurich, Switzerland
Diffusing capacity for nitric oxide (DLNO)
DLNO (in ml/min/mmHg) measured at 80% of the gas exchange threshold during cycling exercise.
Time frame: At second study visit
Diffusing capacity for nitric oxide (DLNO)
DLNO (in ml/min/mmHg) measured at 80% of the gas exchange threshold during cycling exercise.
Time frame: At third study visit, approximately 1-2 weeks after second study visit
Diffusing capacity for nitric oxide (DLNO)
DLNO (in ml/min/mmHg) measured at 50% of the gas exchange threshold during cycling exercise.
Time frame: At second study visit
Diffusing capacity for nitric oxide (DLNO)
DLNO (in ml/min/mmHg) measured at 50% of the gas exchange threshold during cycling exercise.
Time frame: At third study visit, approximately 1-2 weeks after second study visit
Diffusing capacity for carbon monoxide (DLCO)
DLCO (in ml/min/mmHg) measured at 50% of the gas exchange threshold during cycling exercise.
Time frame: At second study visit
Diffusing capacity for carbon monoxide (DLCO)
DLCO (in ml/min/mmHg) measured at 50% of the gas exchange threshold during cycling exercise.
Time frame: At third study visit, approximately 1-2 weeks after second study visit
Diffusing capacity for carbon monoxide (DLCO)
Agreement in DLCO (in ml/min/mmHg) measured at 80% of the gas exchange threshold during cycling exercise.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: At second study visit
Diffusing capacity for carbon monoxide (DLCO)
Agreement in DLCO (in ml/min/mmHg) measured at 80% of the gas exchange threshold during cycling exercise.
Time frame: At third study visit, approximately 1-2 weeks after second study visit
Alveolar volume (VA)
VA (in L) measured at 50% of the gas exchange threshold during cycling exercise.
Time frame: At second study visit
Alveolar volume (VA)
VA (in L) measured at 50% of the gas exchange threshold during cycling exercise.
Time frame: At third study visit, approximately 1-2 weeks after second study visit
Alveolar volume (VA)
Alveolar volume (in L) measured at 80% of the gas exchange threshold during cycling exercise.
Time frame: At second study visit
Alveolar volume (VA)
Alveolar volume (in L) measured at 80% of the gas exchange threshold during cycling exercise.
Time frame: At third study visit, approximately 1-2 weeks after second study visit
Breath hold time (BHT)
BHT (in s) measured at 80% of the gas exchange threshold during cycling exercise.
Time frame: At second study visit
Breath hold time (BHT)
BHT (in s) measured at 80% of the gas exchange threshold during cycling exercise.
Time frame: At third study visit, approximately 1-2 weeks after second study visit
Breath hold time (BHT)
BHT (in s) measured at 50% of the gas exchange threshold during cycling exercise.
Time frame: At second study visit
Breath hold time (BHT)
BHT (in s) measured at 50% of the gas exchange threshold during cycling exercise.
Time frame: At third study visit, approximately 1-2 weeks after second study visit