This study evaluates direct switching vs use of a bridging dose from insulin glargine to insulin degludec in type 1 DM patients. Half of the participants will receive a bridging insulin glargine dose along with the 1st dose of degludec, while other half will receive a placebo and 1st dose of degludec.
Insulin degludec (IDeg), an ultra-long-acting basal insulin, is increasingly used to treat patients with type 1 diabetes (T1D). IDeg has a half-life of 25 hours and duration of action exceeding 42 hours in patients with T1D and as a result does not require as stringent a dosing schedule as other basal insulins. However, steady state concentration of IDeg is not reached until 2 to 3 doses are administered daily, and this may result in greater glycemic variability in the 24 to 72 hours following the initiation of therapy with IDeg. Our hypothesis is that among patients who transition from insulin glargine to IDeg, those who use a bridging dose of insulin glargine will not have a significant change, on average, in time spent in target glycemic range during the transition period, whereas, those transitioning directly to IDeg will have a significant change in this parameter. We further hypothesize that those using the bridging dose of insulin glargine will have less hypoglycemia, less hyperglycemia and need fewer correction boluses than the direct-conversion patients during the transition period. Though IDeg is being increasingly used in clinical practice, there are no guidelines on what is the best way to transition patients from other long-acting insulins, such as glargine, to IDeg. The package insert recommends 1:1 dose conversion from other basal insulins to IDeg, but this does not account for the time taken by IDeg to achieve steady state (typically 48-72 hours). There is no guidance on what to do in those 48-72 hours. Given the time taken for IDeg to achieve steady state, the period of transition from one insulin to another, can result in significant glycemic variation in the 24-72 hours after the first dose. We want to study how best to avoid or minimize this and the option of using a small dose of their original long-acting insulin has anecdotal evidence of success in our practice.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
QUADRUPLE
Enrollment
59
Insulin Degludec injection
Insulin Glargine injection
9g/L sodium chloride (normal saline) subcutaneous injection manufactured to mimic insulin glargine injection
University of Washington Medicine Diabetes Institute at South Lake Union
Seattle, Washington, United States
Mean Change in Percent Time in Range
Change in percent time spent in target glycemic range (TIR, glucose 70-180 mg/dL, both values included) in the 48 hours before and the 48 hours after the 1st dose of IDeg.
Time frame: 48 hours prior to 48 hours after 1st dose of degludec insulin
Coefficient of Variation (CV) of Percent-time-in-range
Change in coefficient of variation of glucose (CV) in the 48 hours before and the 48 hours after the 1st dose of IDeg, as noted on study continuous glucose monitor (dexcom G6)
Time frame: 48 hours prior to 48 hours after 1st dose of degludec insulin
Nocturnal Percent Time in Range of 70-180 mg/dL Nocturnal Time in Range (N-TIR)
Change in nocturnal (defined as midnight to 0600 hours) time in range (glucose in 70-180 mg/dL range) in the 48 hours before and the 48 hours after the 1st dose of IDeg, as noted on study continuous glucose monitor (dexcom G6)
Time frame: 4 days: Outcome Measure Time Frame 48 hours prior to 48 hours after 1st dose of degludec insulin
Percent Time Above 180 mg/dL (TAR-1)
Change in time above range (glucose in 181-250 mg/dL range, TAR-1) in the 48 hours before and the 48 hours after the 1st dose of IDeg, as noted on study continuous glucose monitor (dexcom G6)
Time frame: 4 days
Time Above Range-2 (TAR-2)
Change in time above range (glucose above 250 mg/dL range, TAR-2) in the 48 hours before and the 48 hours after the 1st dose of IDeg, as noted on study continuous glucose monitor (dexcom G6)
Time frame: 4 days
Time Below Range-1 (TBR-1)
Change in time below range (glucose 54-70 mg/dL range, TBR-1) in the 48 hours before and the 48 hours after the 1st dose of IDeg, as noted on study continuous glucose monitor (dexcom G6)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: 48 hours prior to 48 hours after 1st dose of degludec insulin
Time Below Range-2 (TBR-2)
Change in time below range (glucose below 54 mg/dL range, TBR-2) in the 48 hours before and the 48 hours after the 1st dose of IDeg, as noted on study continuous glucose monitor (dexcom G6)
Time frame: 48 hours prior to 48 hours after 1st dose of degludec insulin
Correction Boluses
Change in the number of daily correction boluses administered in the 48 hours before and 48 hours after the 1st dose of degludec insulin, as noted on insulin logs maintained by participants
Time frame: 48 hours prior to 48 hours after 1st dose of degludec insulin