Eligible subjects meeting the pathological profile will be recruited at the designated site by the study personnel. Following subject consent, the subjects will be evaluated for eligibility based on their health condition and history. The ACR \| U.S. kit, in its original packaging, along with the ACR \| U.S. smartphone application will be provided to the subject in a simulated home- use environment. All subjects will be provided with a list of tasks to complete, including providing a urine sample and operating the ACR \| U.S. device on 2 mobile phones. After completing the test, the lay user will complete a post-test questionnaire. The study observer will also complete a questionnaire to collect information regarding the lay users' use of the ACR \| U.S. The device use will be compared with identified risks to determine if the percentage of failures is acceptable. Additionally, measurable usability criteria for specific, critical steps will be evaluated. Following the usability test performed by the lay user, the subjects' urine samples will be tested by the study staff using the comparator device. These results will be considered as the "true value".
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
250
Each study participant will test their urine sample using the ACR \| U.S. test device - a home-use device intended for the semi-quantitative measurement of ACR in the urine (albumin and creatinine ratio) and used to aid in the management of kidney health.
Upon completion of the test using the ACR \| U.S. device, each urine sample will be provided to a professional user for further urine analysis test using the comparator device, the URiSCAN Optima Urine Analyzer.
AccuMed research associates
Garden City, New York, United States
PMG Research of Charleston
Charleston, South Carolina, United States
Accuracy Evaluation: The Degree of Agreement (%) of the ACR | U.S. Urine Analysis Test System as Compared to the Comparator Device
The primary objective of the study is to evaluate the % exact match (percent agreement) and the % ±1 block match (percent agreement) of ACR \| U.S. Urine Analysis Test System (tested by the lay user) compared to the URiSCAN Optima Urine Analyzer (the comparator device, tested by a healthcare professional user), for all reported values (blocks). Different concentrations reported by the ACR \| U.S. Urine Analysis Test System were compared with results from the comparator device.
Time frame: 2 months
Usability Evaluation: User Performance Analysis
The usability of the ACR \| U.S. Urine Analysis Test System was determined by evaluating the percentage of study subjects able to perform all required steps and successfully complete the test given only the instructions and training materials provided. In addition, each subject was asked to complete a post test questionnaire to assess the device ease of use by rating the various test steps on a scale of 1 to 5, with 5 being the easiest ("very easy") and 1 the hardest ("very hard"). This questionnaire also included understanding questions in a multiple-choice, quiz-like format, to assess the participants' understanding of essential information and key test procedures in the study.
Time frame: 2 months