The aim of this study is to explore the acceptability and feasibility of a novel medical device system for autonomously monitoring of breath and heart sounds in Covid-19 (detecting and monitoring the progression of Covid-19 pneumonitis, by evaluating sounds captured through a wearable device (Senti)). As a first-in-man study, the investigators will investigate the safety of the Senti device, the usability and acceptability of the device; and ensure technical and practical feasibility of the device in a real-world clinical setting. Healthcare resources have been stretched substantially by Covid-19. Devices which enable patients to be monitored at home and direct these precious resources to those who require them are needed more than ever. 10 patients will be recruited (the study participants) in two tranches (6 and 4) who are being discharged from A\&E into the community, with Covid-19. These patients will wear the Senti device. The first tranche will use the device over a single session lasting 20 minutes only. The second tranche (which will include patients from tranche one, and which will only proceed if no adverse events are detected in tranche one), participants will wear the device at their discretion (particularly encouraged to wear overnight) over the course of 5 days. The investigators will survey the study participants to answer three key questions: What is the feasibility of the Senti data-capture device? Is this device usable in clinical practice? What are the requirements to train patients to use the device? The investigators will also consider: Does the device function technically and practically, in real-world clinical scenarios? What are the key expected and unexpected safety issues related to using the device (with a particular emphasis on whether the device is likely to cause pressure sores)? These questions will establish the feasibility of using the Senti data capture device as part of a novel medical device system for the autonomous evaluation and monitoring of bioacoustic signals for Covid-19.
TITLE: Remote Evaluation and Monitoring of Acoustic Pathophysiological parameters with external sensor technology in Covid-19. DESIGN: First-In-Man and Feasibility study of the Senti Version 1 Device in Covid-19. AIMS: To explore the acceptability and feasibility of a novel medical device for the remote monitoring and evaluation of acoustic pathophysiological parameters in Covid-19. To investigate usability and acceptability of the Senti data capture device, and to ensure technical and practical functionality of the device in a real-world clinical scenario. PRIMARY OUTCOMES: Device feasibility SECONDARY OUTCOMES: Length of time with the device in situ. The ease with which patients can apply the device. POPULATION ELIGIBILITY: Patients with covid-19 or suspected of having Covid-19 clinically, being discharged home into the community after attending A\&E. DURATION: 3 Months. (Recruitment period: 2 months. Analysis and reporting: 1 month).
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DEVICE_FEASIBILITY
Masking
NONE
Enrollment
10
This device class I, CE marked garment, with a similar form to a T-Shirt, embedded with ten sensor modules encased in silicone; the device comes with a charging stand in the form of a clothes hanger. Depending on the outcome of this feasibility study, the device may, in the future, form part of a class IIb medical device system, when accompanied by cloud-based software to listen to both current and historically recorded breath sounds for each Senti patient. The Senti Version One device will be labelled clearly to indicate the device version, on the inside of the garment, conforming to the MDR. The garment itself will be made from textile composite, including cotton, elastase, micromodel, spandex, and polyester. All other components (including electronic and other plastic components) will be entirely encased in medical-grade silicone.
Senti Tech
Liverpool, Merseyside, United Kingdom
Patient-rated device acceptability
Patient questionnaire "on a scale of 1 ("I would not approve at all") to 5 ("I would greatly approve and would like this to become standard practice"), to what extent would you approve of this device being used to enable clinicians to assess your heart and lung sounds as part of a telephone consultation?"
Time frame: 1 month
Patient-rated device comfort
Patient questionnaire "on a scale of 1 ("Very difficult to use") to 5 ("Very easy to use"), how easy to use is the device?"
Time frame: 1 month
Patient-rated device ease of use
Patient questionnaire "on a scale of 1 ("Too uncomfortable to use for more than an hours or so") to 5 ("As comfortable as a T-Shirt"), how comfortable is the device?"
Time frame: 1 month
Expert-rated device data quality
An appropriately qualified person (with clinical experience of auscultation) to rate quality of data captured by the device, as compared subjectively against the quality that they typically expect from standard auscultation, on a scale of 1 ("Much poorer data quality \[than standard auscultation\]") to 3 ("equivocal data quality") to 5 ("Much higher data quality").
Time frame: 1 month
Adverse events and adverse device events
The number of participants experiencing adverse events, both arising from use of the device or otherwise, will be reported. Adverse events will be categorised as unexpected or expected, serious or otherwise, device-related or un-related.
Time frame: 1 month
Length of time spent with the device on the patient.
Length of time over which a patient has used the device, as measured using a structured, binned multiple-choice survey. This is a custom-made scale titled "In the past 24 hours, for how many hours have you worn the Senti device?" with a minimum value of 0 hours and a maximum value of 24 hours. 8 options which include a range of times are available for selection.
Time frame: 1 month
Length of time taken for the patient to apply the device
Length of time taken for the patient to put the device on, as measured by an investigator with a stop watch.
Time frame: 1 month
Time spent to train patients to use the device.
Length of time taken to train patients to use the device, as measured by an investigator with a stop watch.
Time frame: 1 month
Pressure sore EPUAP grade
For those patients who develop pressure sores, the pressure sore will be graded using the European Pressure Ulcer Advisory Panel grading system from a grade of grade 1 through to grade 4, including unclassified gradings and moisture lesions. (Patients will be graded as "No pressure sores" if there are no pressure sores noted on examination).
Time frame: 1 month