The Covid-19 pandemic requires a reliable diagnosis of patients in order to take care of them in the best conditions and in the appropriate services. Moreover, the current diagnostic reference is reverse transcription by polymerase chain reaction (RT-PCR) on a nasopharyngeal sample taken by swab. This technique is expensive (54€) and its production time is several hours. Alternative methods are in progress, including, rapid diagnostic tests. The MEMS microfluids and nanostructures (MMN) laboratory, in partnership with the Institut Chimie Biologie Innovation (CBI) (Paris, 75005), have developed a portable test "COVIDISC", low-cost (10 €), fast (1 hour), including extraction, elution and amplification in solid medium isothermal, reverse amplification loop mediated transcription (RT-LAMP). The "lab" version has received an analytical validation on human nasopharyngeal samples with performance comparable to classic RT-PCR (sensitivity of 7 copies per μl, specificity 100%). The objective of this study is to validate the in vitro diagnostic medical device, COVIDISC, with the standard nasopharyngeal RT-PCR test.
All outpatients and hospitalized patients (intensive care unit, internal medicine service and emergency service) will be proposed to participate to the study after assessment of eligibility criteria by the investigator. The investigator will collect a written consent of the patient or from the support person or a familiar if, the patient is not in condition to consent. Patient's participation will be notified in his medical record. After inclusion of patient, the nurse will collect general and clinical data and 2 nasopharyngeal swabs will be taken. One sample to test the prototype of the RT-LAMP and the second one to carry out the classic RT-PCR. The results will be collected and compared in a second step.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
192
2 nasopharyngeal swabs taken for PCR and COVIDISC
CHI Robert Ballanger
Aulnay-sous-Bois, France
Comparaison of the performance of the diagnostic performance (sensitivity, sensibility) of RT-LAMP test using the RT-PCR test as a reference.
Calculate sensitivity, Specificity, Positive predictive value, Negative predictive value, Positive and negative likelihood report COVIDISC fast, antigenic test compared to RT-PCR Covid-19 reference test conducted in the laboratory
Time frame: Day 0
Compare the diagnostic performances of RT-LAMP to clinical diagnosis.
The result of RT-LAMP test versus clinical evaluation defined by the clinical symptoms of the patients at the time of nasopharyngeal swab.
Time frame: Day 0