Reduction of elevated pressure in the eye (Intraocular pressure, or 'IOP') with eye drop medications has been shown to be effective in delaying or preventing the progression of glaucoma, and it is the only proven method for reducing the risk of glaucomatous visual field loss. This study is being conducted to determine how well DE-126 ophthalmic solution works (efficacy) in safely lowering IOP when dosed as topical eyedrops. This study will evaluate the safety and efficacy of DE-126, ophthalmic solution in subjects with Primary Open Angle Glaucoma (POAG) or Ocular Hypertension (OHT). The IOP will be measured at 3 different times throughout the day, over 4 total visits during a 3-month treatment period (with up to 4 extra weeks observation if the patient must stop taking current eye drops to lower IOP). Safety assessments will be done throughout the study, including ocular signs and symptoms, and vital signs. While the most important time-point to measure IOP in this study and evaluate efficacy will be at the final study visit (month 3), IOP values will also be evaluated at other visits throughout the 3-month treatment period.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
323
DE-126 Ophthalmic Solution QD evening and Vehicle QD Morning
Timolol Maleate Ophthalmic Solution BID (morning and evening)
Arizona Eye Center
Chandler, Arizona, United States
Arizona Glaucoma Specialists
Phoenix, Arizona, United States
Walman Eye Center
Sun City, Arizona, United States
Global Research Management
Glendale, California, United States
Premiere Practice Management
Los Angeles, California, United States
Intraocular Pressure at Week 2
Intraocular pressure (IOP), the fluid pressure inside the eye was measure by the Goldmann applanation tonometer in millimeters mercury (mmHg) at 3 time-points throughout the day. Analysis using Mixed-effects Model for Repeated Measures (MMRM).
Time frame: 08:00, 10:00 and 16:00 at Week 2
Intraocular Pressure at Week 6
Intraocular pressure (IOP), the fluid pressure inside the eye was measure by the Goldmann applanation tonometer in millimeters mercury (mmHg) at 3 time-points throughout the day. Analysis using Mixed-effects Model for Repeated Measures (MMRM).
Time frame: 08:00, 10:00 and 16:00 at Week 6
Intraocular Pressure at Month 3
Intraocular pressure (IOP), the fluid pressure inside the eye was measure by the Goldmann applanation tonometer in millimeters mercury (mmHg) at 3 time-points throughout the day. Analysis using Mixed-effects Model for Repeated Measures (MMRM).
Time frame: 08:00, 10:00 and 16:00 at Month 3
Mean Diurnal Intraocular Pressure at Month 3
Mean diurnal Intraocular Pressure (IOP) was defined as the mean of the IOP valued at the three schedules timepoints (8:00, 10:00 and 16:00) at that visit for that subject.
Time frame: Three months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
North Valley Eye Medical Group
Mission Hills, California, United States
The Eye Research Foundation
Newport Beach, California, United States
University of California, Los Angeles, Doheny Eye Centers
Pasadena, California, United States
North Bay Eye Associates, Inc
Petaluma, California, United States
Sacramento Eye Consultants
Sacramento, California, United States
...and 31 more locations