This project is set to compare the wrist joint movement measurements of the DyCare® Lynx System with optoelectronic motion analysis using a marker system and infrared cameras. A total of 10 healthy test persons will be subjected to both the DyCare® Lynx and the Vicon® measurements during standard movements as well as during activities of daily living. The wrist joint angles measured with both systems will be compared.
The accepted laboratory gold standards for human motion analysis are too over-elaborated for clinical use. The DyCare® Lynx system is user-friendly and has been proven reliable for motion evaluation of different joints, but not yet for the wrist. Therefore, this project is set to compare the wrist joint movement measurements of the DyCare® Lynx System with optoelectronic motion analysis using a marker system and infrared cameras. DyCare® Lynx is based on two inertial sensors (DyTrack) capable of objectively measuring three dimensional joint movements in real time. Each inertial sensor includes an accelerometer, gyroscope and magnetometer and captures up to 1'000 samples per second. DyCare® Lynx is certified for measurements on the human musculoskeletal apparatus (EN ISO 13485:2003 Certificate No. 15185 - M), is CE marked and will only be applied to each participant for a few minutes during the measurements. The control measurements will be conducted using a Vicon® motion capture system in the Motion Analysis Laboratory of the Department of Plastic Surgery and Hand Surgery of the University Hospital of Zurich. The Vicon® system is equipped with 11 infrared cameras. The system is made for 'Life science application' and is approved as CE medical device. A total of 10 healthy test persons will be subjected to both the DyCare® Lynx and the Vicon® measurements during standard movements as well as during activities of daily living. The wrist joint angles measured with both systems will be compared, therefore limits of agreement, maximum difference and root mean squared difference will be calculated to quantify the deviation between methods. The standard error of measurements will be calculated to determine repeatability of the systems.
Study Type
OBSERVATIONAL
Enrollment
10
Motion analysis using DyCare® Lynx system with inertial based sensors as well as an optoelectronic motion analysis system based on infrared cameras (11x Vicon infrared high speed cameras)
University Hospital Zurich, Clinic of Reconstructive Surgery
Zurich, Canton of Zurich, Switzerland
Active wrist movement at standard movements
Ten healthy subjects will be recorded (3D motion analysis) while performing flexion-extension and radial-ulnar deviation movements of their right wrist using inertial sensors and skin markers
Time frame: October 2019
Active Wrist movement during activities of daily living.
Ten healthy subjects will be recorded (3D motion analysis) while performing during ADLs: opening a jar, opening a lid pot, turning a key, dart-throwing.
Time frame: January 2020-August 2021
Comfort of the wearable Sensors
questionnaire looking into six dimensions of comfort as proposed by Knight and Baber (Knight, J.F.; Baber, C. A tool to assess the comfort of wearable computers. Human Factors 2005, 47, 77-91, doi:10.1518/0018720053653875.
Time frame: October 2019
Time Consumption of measurements using DyCare® Lynx
Minutes necessary to attach the sensors to the patients and to record the movements.
Time frame: October 2019