The objectives of this study are to explore the efficacy and safety of a robotic procedure for a minimally invasive cochlear implantation.
The cochlear implant (CI) is a neural prothesis and has been the gold standard treatment for severe to profound sensorineural hearing loss over several decades. The surgical procedure for cochlear implantation surgery aims to atraumatically insert the electrode array of the cochlear implant into the cochlea. However, due to the location of the cochlea inside the skull, the surgeon is required to initially create an access from the surface of the temporal bone to the cochlea (inner ear). In conventional methods, this access is acquired by removal of large portions of the mastoid bone through a wide mastoidectomy and posterior tympanotomy. The outcome and success of the conventional procedure varies due to mainly two factors: surgeon skill and subject anatomical variation. To overcome these variables toward a more consistent and less invasive cochlear implantation surgery, the development of robotic and image guided cochlear implantation has taken place. This study primarily aims to explore the efficacy of the HEARO robotic cochlear implantation surgery. Primary Objective The primary objective of this study is to: • explore the efficacy of a minimally invasive direct cochlear access via the HEARO procedure. Secondary Objectives The secondary objectives of this study are to: * explore the safety of a minimally invasive direct cochlear access via the HEARO procedure. * exploratively evaluate the electrode array insertion outcomes through the direct tunnel access.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
OTHER
Masking
NONE
Enrollment
10
Cochlear implant surgery with HEARO procedure
CHU Montpellier
Montpellier, France
Electrode array insertion
• Relative ratio of successful electrode array insertions through the drilled direct cochlear access with the HEARO procedure to the total HEARO procedures (i.e. proportion of successful insertions with the procedure out of the total number of patients included in the study).
Time frame: During surgery
Electrode array insertion outcome (efficacy)
• The angular insertion depth will be evaluated.
Time frame: During surgery
Electrode array insertion outcome (efficacy)
• The number of contacts inserted will be evaluated.
Time frame: During surgery
Electrode array insertion outcome (efficacy)
• The tip-fold over will be evaluated.
Time frame: During surgery
Electrode array insertion outcome (efficacy)
• The scalar deviation will be evaluated.
Time frame: During surgery
Insertion depth prediction accuracy (efficacy)
• The insertion depth prediction accuracy as the difference between the estimated insertion depth of the electrode at the planning and the actual insertion depth.
Time frame: During surgery
Absolute angular accuracy of the drilled tunnel access (safety)
• The absolute lateral accuracy of the drilled tunnel to the facial nerve and chorda tympani is measured as the difference between the planned trajectory and the actual drilled trajectory distance.
Time frame: During surgery
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Absolute lateral accuracy of the drilled tunnel at the target (safety)
• The absolute lateral accuracy of the drilled tunnel is measured as the distance between the planned target trajectory position and actual target of the drilled trajectory position.
Time frame: During surgery
Ratio of the round window membrane preservation during the inner ear access (safety)
• The ratio of the preserved round window (RW) membrane at the robotic inner ear access by visual inspection. This will be assessed as subjective evaluation by the surgeon.
Time frame: During surgery
Timing of the HEARO procedure
• The timing of the different steps of the HEARO procedure will be recorded.
Time frame: During surgery
Adverse events (safety)
• Adverse events will be recorded
Time frame: During surgery