Acute compartment syndrome (ACS) after revascularization for acute limb ischemia is a potentially limb-threatening condition and requires urgent fasciotomy. Compression ultrasound (CU) is an established method for measuring intravenous pressure in superficial veins and, for example, can determine central venous pressure in critically ill patients. In cadaver studies, compression ultrasound has been proven to correlate with invasive intra compartmental pressure (ICP) measurements. This study aims to determine CU's added diagnostic value compared to ICP in detecting ACS after revascularisation.
Acute compartment syndrome (ACS) after revascularization for acute limb ischemia is a potentially limb-threatening condition and requires urgent fasciotomy. It occurs when the tissue pressure within a closed muscle compartment exceeds the perfusion pressure and results in muscle and nerve ischemia. If clinically suspected, intra- compartmental pressure (ICP) is measured by inserting a needle into the area of ACS, usually the anterior tibial muscle compartment, while an attached pressure monitor records the pressure. This invasive diagnostic method is widely used as a standard with a sensitivity of 94% and specificity of 98%. Compression ultrasound (CU) is an established method for measuring intravenous pressure in superficial veins and, for example, can determine central venous pressure in critically ill patients. An ultrasound translucent probe measures the pressure applied on the skin surface with the ultrasound transducer. In cadaver studies, compression ultrasound has been proven to correlate with invasive ICP measurements. The elasticity ratio (ER, compartment diameter with and without external pressure) validated in a recently published animal model has a sensitivity of 94.4% and a specificity of 88.9% to diagnose a compartment syndrome properly. The first results in six trauma patients showed that the ER less than 10,5% of the anterior tibial compartment had a sensitivity of 95,8% and a specificity of 87,5% to an appropriate diagnosis of ACS. Thus, this non-invasive, low-cost, and secure diagnostic technique has not been validated in patients with ACS after revascularisation for acute lower limb ischemia yet has the potential to discriminate clinically suspected ACS sensitively. This study aims to determine CU's added diagnostic value compared to ICP in detecting ACS after revascularisation.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
38
After successful revascularisation for acute ischemia and clinical suspicion of acute compartment syndrome, compression ultrasound (CU) will be performed in OR followed by standard intra-compartmental measurement. Two physicians will perform two subsequent measurements of the affected limb after revascularisation. The unaffected limb will be examined once to obtain baseline elasticity ratio values. All CU examinations will be documented in PACS (picture archiving and communication system) and evaluated after ICP measurement, and if necessary, fasciotomy is performed.
Kantonsspital Aarau
Aarau, Canton of Aargau, Switzerland
RECRUITINGElasticity ratio (ER)
Sensitivity and specificity of elasticity ratio measured by compression ultrasound for detecting high intra compartmental pressure
Time frame: baseline
Inter- and intra-rater reliability
Inter- and intra-rater reliability of compression ultrasound
Time frame: baseline
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.