Vasoplegia is a common complication after heart surgery for heart failure. With vasoplegia, the blood vessels can no longer squeeze properly, causing low blood pressure that is sometimes difficult to treat with medication. One of the causes of this complication is likely to be the use of the heart-lung machine, a device that takes over the function of the heart and lungs during surgery. The blood then comes into contact with a foreign environment and this can cause a reaction of the immune system. Patients with heart failure are extra sensitive to this reaction. CytoSorb device is a filter that can be built into the heart-lung machine and can reduce the response of the immune system. Therefore, this study aims to investigate whether the use of this filter during heart surgery in patients with heart failure results in a less frequent occurrence of vasoplegia after surgery.
The incidence and prevalence of chronic heart failure is increasing. Despite the expansion of therapeutic options, overall survival and quality-of-life remain poor. When optimal medical therapy and cardiological interventions have failed to improve a patient's condition, surgical intervention may be a valid option in order to improve cardiac function. Different surgical treatments have improved clinical outcome. Unfortunately, heart failure surgery is associated with an increased risk of vasoplegia. This syndrome is characterized by hypotension and the continuous need of vasopressors, despite a normal or high cardiac index. The incidence of vasoplegia ranges from 11-31% in patients undergoing heart failure surgery. The prognosis of vasoplegia is poor. Prolonged hypotension and the accompanying hypoperfusion lead to end-organ dysfunction and is associated with an increased morbidity and mortality. The investigators hypothesise that the balance of the vascular system of patients with heart failure is fragile and therefore could easily be disturbed by a systemic inflammatory response syndrome (SIRS) caused by the cardiopulmonary bypass (CPB) and surgical trauma, making these patients more prone to develop vasoplegia. Minimising this SIRS reaction could be a strategy to prevent vasoplegia. Therefore, the objective of this single-center, investigator-initiated study is to analyse the efficacy and cost-effectiveness of using CytoSorb in preventing vasoplegia in patients with heart failure undergoing cardiac surgery on CPB. CytoSorb treatment will be conducted intraoperatively and the device will be applied in a parallel circuit in the CPB. The total study intervention protocol takes 5 days and starts on the day of the surgery (day 0) and ends at day 4 postoperatively. Patient clinical data will be collected until day 30. The vascular reactivity in response to a vasoconstrictor will be assessed in all patients at 3 different time points (after induction, after CPB, on day 1 postoperatively). During the vasoconstriction test, a bolus of 2 μg/kg phenylephrine is administered intravenously, after which the effect on the systemic vascular resistance is registered. At the same time points and in addition, before induction (baseline) and on day 4 the sublingual microcirculation will be monitored and blood samples will be collected.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
QUADRUPLE
Enrollment
36
The CytoSorb device will be placed in the CPB circuit in half of the study population during their cardiac operation.
Leiden University Medical Center
Leiden, Netherlands
RECRUITINGDelta systemic vascular resistance index (SVRi) after CPB.
The change in SVRi after the administration of phenylephrine after cessation of CPB.
Time frame: during surgery (2-10 hours)
Incidence of vasoplegia.
Vasoplegic syndrome defined as the continuous need of vasopressors (norepinephrine ≥0.2 μg/kg/min for at least 12 consecutive hours, terlipressin, or methylene blue) in combination with a cardiac index (CI) ≥2.2 l/min/m2 for at least 12 consecutive hours, starting within the first 3 days postoperatively.
Time frame: 72 hours
Delta SVRi in ICU.
The change in SVR after the administration of phenylephrine during the postoperative day one in the Intensive Care Unit (ICU).
Time frame: postoperative day 1
Total administered dosage of vasopressors.
Time frame: 30 days
Change in IL-6, IL-8, IL-10 levels.
Time frame: until postoperative day 4 (96 hours)
Change in microvascular flow index [MFI],heterogeneity index [HI].
Heterogeneity index \[HI\] will be calculated as the difference between the highest MFI minus the lowest MFI and divided by the mean MFI.
Time frame: until postoperative day 4 (96 hours)
Change in capillary density, functional capillary density [FCD], total vessel density [TVD], perfused vessel density [PVD].
Time frame: until postoperative day 4 (96 hours)
Change in proportion of perfused vessels [PPV].
Time frame: until postoperative day 4 (96 hours)
Change in rolling leucocytes [RL] levels.
Time frame: until postoperative day 4 (96 hours)
Change in mean cell velocity [MCV], red blood cell velocity [RBCv].
Time frame: until postoperative day 4 (96 hours)
Change in capillary hematocrit.
Time frame: until postoperative day 4 (96 hours)
Change in mean arterial pressure (MAP) after phenylephrine administration.
Time frame: until postoperative day 1 (24 hours)
Hours on mechanical ventilation.
Time frame: 30 days
Hours on mechanical circulatory support.
Time frame: 30 days
Hours on postoperative renal replacement therapy.
Time frame: 30 days
End organ damage (kidney dysfunction).
Time frame: 30 days
Change in total Sequential Organ Failure Assessment Score (SOFA).
Time frame: 30 days
Amount of used resuscitation fluids.
Time frame: 30 days
Amount of used blood transfusion products.
Time frame: 30 days
Length of ICU stay.
Time frame: 30 days
Length of hospital stay.
Time frame: 30 days
30-Day hospital readmissions.
Time frame: 30 days
All-cause mortality.
Time frame: 30 days
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.