This study is to evaluate the sensitivity and intra-/inter-observer agreement of the averaged magnetization inversion recovery acquisitions (AMIRA) in spinal cord (SC) Multiple sclerosis (MS) lesion detection and to evaluate the additional clinical value of this sequence in clinical settings.
An averaged magnetization inversion recovery acquisitions (AMIRA) sequence was proposed for SC MRI. This MR-sequence delivers excellent contrast between the SC gray and white matter as well as between the SC and cerebrospinal fluid (CSF) in clinically feasible-acquisition times. Moreover, the high quality and in-plane resolution of AMIRA images allows for segmentation of the SC gray and white matter with high accuracy and reproducibility. This study is to evaluate the sensitivity and intra-/inter-observer agreement of the averaged magnetization inversion recovery acquisitions (AMIRA) in spinal cord (SC) Multiple sclerosis (MS) lesion detection and to evaluate the additional clinical value of this sequence in clinical settings.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
10
SC MRI (Averaged Magnetization Inversion Recovery Acquisitions (AMIRA), standard conventional SC MRI sequences, additional sequences for spinal cord MRI (sagittal-2D or 3D short tau inversion recovery, sagittal-2D or 3D phase-sensitive inversion recovery, 3D magnetization prepared 2 rapid acquisition gradient echoes (MPRAGE)). To evaluate the presences of ongoing inflammation (acute or chronic) in the SC of patients, 3D MPRAGE and 3D fluid-attenuated inversion recovery images after intravenous gadolinium (Gd) contrast administration (0.1 mmol per kg body weight) will be acquired.
12-item multiple sclerosis walking scale (MSWS-12) questionnaire: self-report measure of the impact of MS on the individual's walking ability
University Hospital Basel, Department of Neurology
Basel, Switzerland
RECRUITINGNumber of SC lesions
Number of SC lesions using AMIRA compared to gold-standard conventional SC MRI sequences
Time frame: one time assessment (60 minutes scheduled per patient for the MRI part including preparation time outside of the scanner and actual scanning time)
Inter-observer agreement on SC lesion count
Inter-observer agreement with regard to lesion detection using AMIRA compared to gold-standard conventional SC MRI sequences.
Time frame: one time assessment (60 minutes scheduled per patient for the MRI part including preparation time outside of the scanner and actual scanning time)
Presence of ongoing inflammation (acute or chronic) in the SC
Presence of ongoing inflammation (acute or chronic) in the SC 3D MPRAGE and 3D fluid-attenuated inversion recovery images after intravenous gadolinium (Gd) contrast administration (0.1 mmol per kg body weight)
Time frame: one time assessment (60 minutes scheduled per patient for the MRI part including preparation time outside of the scanner and actual scanning time)