This a multi-center, open label, non-comparative, study that will evaluate the clinical safety and performance of Exufiber Ag+ and Exufiber dressings, separately, when used as intended in moderate to high exuding partial thickness burns (PTBs) through assessment of wound progression from baseline to the Subject's last clinical follow-up visit. Sixty-eight (68) eligible subjects, with moderate to high exuding partial-thickness burns, will be selected for treatment with either Exufiber Ag+ silver-coated gelling dressing, or Exufiber gelling dressing. The study will last 5 weeks, with a requirement of 5 study visits in total, including dressing changes at each study visit.
This is a multi-center study taking place in the United States, and conducted at 3-4 sites/locations. It is designed as an open, non-comparative study to test the safety and performance of Exufiber Ag+ and Exufiber in managing burn healing. The primary objective of this study is to evaluate the clinical safety and performance of all study dressings, separately, when used as intended in moderate to high exuding partial thickness burns (PTBs) through assessment of wound progression from baseline to the Subject's last clinical follow-up visit. The dressings are intended to promote healing through the management of the wound environment. Sixty-eight (68) subjects with partial thickness burns will be treated with either Exufiber Ag+ (34 subjects) or Exufiber (34 subjects) primary dressings, at the discretion of the Investigator. Secondary dressings should be non-adherent, non-antimicrobial dressings (local treatment praxis). Each Subject will be evaluated at five (5) planned study visits for a maximum total treatment period of up to 21 days, unless the burn heals. Visit 1 is a baseline visit to enroll Subjects and determine burn extent. Each Subject will be assigned to either Exufiber Ag+ or Exufiber primary dressings and treated according to the Instructions for Use (IFU) and the local clinical routine. Visit 2 is a Confirmation Visit at up to 3 days, where the Investigator will confirm the burn meets study eligibility, and has not progressed to a full-thickness burn. Visits 3, 4, and 5 are follow-up visits at days 7, 14, and 21, respectively, from the date of the primary dressing application. At each follow-up visit the Subject will return to the clinic for evaluation and primary dressing change. Wound progression will be determined by the Investigator at each study visit and measured by three outcome variables (Deteriorated, No Change, Improved). Images of the wound at each follow up visit will be analyzed to determine changes in wound size. Secondary endpoints will be collected identically at each visit at each clinical site to assess safety and performance of the dressings. The secondary objectives are: * To evaluate time to discontinuation of study dressings from baseline to the last clinical follow-up visit, up to 21 days. * To evaluate clinical outcomes of the study wound from baseline to the last clinical visit up to 21 days. * To evaluate epithelization from baseline to the last clinical follow-up visit up to 21 days based on digital photo imaging software measurements. * To evaluate a change in wound size from baseline to the last clinical follow-up visit up to 21 days based on digital photo and imaging software measurements. * To evaluate healing status, including exudate levels, infection status, and proportion of burn healed, by clinician's visual judgement, at Confirmation Visit (up to 72 hours) and at each clinic follow-up visit, up to 21 days. * To evaluate Subject-reported pain at application, during wear, and at dressing changes through questionnaires at each clinic follow-up visit up to 21 days. * To evaluate treatment and dressing selections, including type and quantity, at application and at each clinic follow-up visit up to 21 days. * To evaluate clinician handling of the dressing at application and at every dressing change performed at the clinic, from baseline and at each follow-up visit up to 21 days. * To evaluate clinician assessment of the dressing at application and at every dressing change performed at the clinic, from baseline and at each follow-up visit up to 21 days.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
44
A sterile nonwoven wound dressing made from highly absorbent PVA fibers.
A sterile nonwoven wound dressing made from highly absorbent PVA fibers, and coated with silver sulphate.
Arizona Burn Center, Valleywise Health
Phoenix, Arizona, United States
Keck Medical Center of USC
Los Angeles, California, United States
MedStar Health Research Institute
Washington D.C., District of Columbia, United States
University of South Florida-Tampa General Hospital
Tampa, Florida, United States
Massachusetts General Hospital
Boston, Massachusetts, United States
Drexel Univerisity
Philadelphia, Pennsylvania, United States
Wound progression
A subjective measurement to determine wound progression since the last visit, determined by three outcome variables: Deteriorated No Change Improved
Time frame: 5 weeks
Time to discontinuation of study dressings
Measured by time (in days) from baseline to last clinical follow-up
Time frame: 5 weeks
Wound Size
Wound size (measured in inches or centimeters), at each study visit, from baseline to last clinical follow-up, using planimetry software to obtain measurements from digital photographs. Measurements to include length, width, and depth.
Time frame: 5 weeks
Re-epithelialization of wound
A measure of re-epithelization tissue, as a percentage of wound, from baseline to last clinical follow-up, using planimetry software to obtain measurements from digital photographs.
Time frame: 5 weeks
Wound Exudate
Evaluate the level of wound exudate, using the variables listed below: Dry Moist Wet Saturated Leaking
Time frame: 5 weeks
Wound Maceration
Determine the presence of wound maceration, using the variables listed below: Yes No
Time frame: 5 weeks
Proportion of Burn Healed
Evaluate the proportion of the burn that is healed, by clinician judgement, using the variables listed below: No healing 0-30% healed 31-70% healed 71-99% healed 100% healed
Time frame: 5 weeks
Blistering
Determine the presence of wound blistering, using the variables listed below: Yes No
Time frame: 5 weeks
Wound Redness/Irritation peri-wound skin
Determine the presence of redness and irritation on the peri-wound skin, using the variables listed below: Yes No
Time frame: 5 weeks
Exudate Nature
Determine the nature of wound exudate, using the variables listed below: Serous Serosanguinous Sanguineous Purulent
Time frame: 5 weeks
Malodor
Determine the presence of wound malodor, using the variables listed below: None Slight Moderate Strong
Time frame: 5 weeks
Burn odor
Determine the presence of burn odor, using the variables listed below: Yes No
Time frame: 5 weeks
Local infection
Determine the presence of signs of local wound infection, using the variables listed below: New / Increasing Pain Delayed / Stalled Healing Purulent discharge Erythema Local Warmth Exudation Odor Pyrexia Induration Leukocytosis Edema / Swelling Eschar
Time frame: 5 weeks
Subject pain
Measured at dressing application, change, and removal, using a patient reported outcome questionnaire that is used to evaluate pain intensity on a validated scale from 0-10. A higher score correlates with greater experienced pain.
Time frame: 5 weeks
Dressing Adherence
Subjective measurement to asses performance of the primary dressing and its adherence to the wound bed, using the variables listed below: Yes No
Time frame: 5 weeks
Rewetting
Subjective measurement to asses performance of the primary dressing and the need for re-wetting prior to removal, using the variables listed below: Yes No
Time frame: 5 weeks
Dressing ability to rehydrate
Subjective measurement to asses performance of the primary dressing and its ability to rehydrate the wound, using the variables listed below: Very poor Poor Good Very good N/A
Time frame: 5 weeks
Dressing ability to retain exudate
Subjective measurement to asses performance of the primary dressing and its ability to retain wound exudate, using the variables listed below: Very poor Poor Good Very good N/A
Time frame: 5 weeks
Dressing ability to absorb blood
Subjective measurement to asses performance of the primary dressing and its ability to absorb blood, using the variables listed below: Very poor Poor Good Very good N/A
Time frame: 5 weeks
Dressing ability to retain slough
Subjective measurement to asses performance of the primary dressing and its ability to retain slough, using the variables listed below: Very poor Poor Good Very good N/A
Time frame: 5 weeks
Dressing ability to clean wound bed
Subjective measurement to asses performance of the primary dressing and its ability to clean the wound bed, using the variables listed below: Very poor Poor Good Very good N/A
Time frame: 5 weeks
Dressing ability to retain gelling properties
Subjective measurement to asses performance of the primary dressing and its ability to retain its gelling properties, using the variables listed below: Very poor Poor Good Very good N/A
Time frame: 5 weeks
Dressing ability to retain balanced moist environment
Subjective measurement to asses performance of the primary dressing and its ability to retain a balanced moist environment, using the variables listed below: Very poor Poor Good Very good N/A
Time frame: 5 weeks
Dressing conformability
Subjective measurement to assess performance of the primary dressing and its ability to conform, using the variables listed below: Very poor Poor Good Very good N/A
Time frame: 5 weeks
Dressing flexibility
Subjective measurements to assess performance of the primary dressing and its flexibility, using the variables listed below: Very poor Poor Good Very good N/A
Time frame: 5 weeks
Ease of dressing application
Subjective measurement to assess the handling of the primary dressing and ease of dressing application, using the variables listed below: Very poor Poor Good Very good N/A
Time frame: 5 weeks
Ease of dressing removal with and without moistening
Subjective measurement to assess the handling of the primary dressing and ease of removal with and without moistening, using the variables listed below: Very poor Poor Good Very good N/A
Time frame: 5 weeks
Dressing removal in one piece
Subjective measurement to assess the handling of primary dressing and its ability to be removed in one piece, using the variables listed below: Yes No
Time frame: 5 weeks
Residuals of dressing material in the wound or surrounding skin
Subjective measurement to assess presence of primary dressing residuals in the wound or surrounding skin at the time of removal, using the variables listed below: Yes No
Time frame: 5 weeks
Bleeding at removal
Subjective measurement to assess presence of bleeding at the time of primary dressing removal, using the variables listed below: Yes No
Time frame: 5 weeks
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.