The goal of this research is to validate novel non-invasive Magnetic resonance imaging (MRI) biomarkers to detect Gastroesophageal varices (GEV) in patients with cirrhosis, including fractional flow change in the portal vein and elevated azygos flow. End-stage liver disease (cirrhosis) is characterized by advanced fibrosis, liver failure, and portal hypertension. There are many causes of cirrhosis, including viral hepatitis, alcohol abuse, and perhaps most importantly, non-alcoholic fatty liver disease (NAFLD) and its aggressive subset, non-alcoholic steatohepatitis (NASH). 3 million new cases of end-stage liver disease (cirrhosis) are expected over the next decade. In cirrhosis, portosystemic collaterals that shunt blood away from the liver develop due to increased portal pressure. Gastroesophageal varices (GEV) are the most clinically relevant because they can cause fatal internal bleeding. GEV bleeding carries \~20% mortality at 6 weeks, and \~34% overall mortality. Identification of at-risk varices, prior to bleeding, is of paramount importance to initiate primary prophylaxis. To identify and treat at-risk patients, current guidelines recommend regular esophagogastroduodenoscopy (EGD) and variceal band ligation. Detection of high-risk GEV is key to initiating primary prophylaxis, which can reduce mortality by 50-70%. However, endoscopy is invasive and often unnecessary when no treatment is required. Therefore, the American Association for the Study of Liver Diseases has identified the development of "non-invasive markers that predict the presence of high-risk varices" as a major unmet need.
The overall goal of this research is to implement advanced non-invasive 4D flow MRI biomarkers to predict the presence of treatable but potentially lethal GEV in patients with cirrhosis. This would facilitate the triage of patients with high-risk GEV to therapeutic EGD, while reducing unnecessary EGD procedures in patients without them. The primary biological mechanism for development of GEV is elevated portal pressure and reversal of flow in the left gastric vein (LGV). Applying 4D flow MRI, investigators aim to detect and quantify reversed flow in the LGV to detect GEV at risk for bleeding. Aim 1: Perform pre-clinical validations of an optimized, accelerated radial 4D flow MRI strategy, and of fat mitigation strategies for radial 4D flow MRI. Aim 2: Determine the diagnostic performance of radial 4D flow MRI, in cirrhotic adults including 1. diagnostic accuracy to identify high-risk GEV using EGD as reference standard, and 2. test-retest repeatability Aim 3: Evaluate the effects and added value of a meal challenge to assess for high-risk GEV. Aim 4: Compare the accuracy of 4D flow MRI to current non-invasive markers of liver disease. Aim 5: Determine the feasibility of radial 4D flow MRI in participants with FALD to detect differences in mesenteric response to a meal challenge when compared to healthy controls and participants with other types of liver disease. Research Procedures Pre-Clinical Validation (Phase 1): A total of 21 participants (7 healthy volunteers, 14 patients with GEV) to evaluate the optimized 4D flow methods, and 20 obese subjects to evaluate fat-mitigation strategies, will be enrolled. Participants will be asked to complete a single research visit that will include a contrast enhanced MRI scan lasting up to 1 hour. Participants will be asked to fast for at least 5 hours prior to the exam. Participants will be screening a final time for contraindications to contrast enhanced MR imaging; an IV will be placed; and participants will be positioned in the MR scanner, asked to lie as still as possible and to follow some breath hold instructions. Clinical Validation (Phase 2-3): A total of 105 patients diagnosed with cirrhosis will be enrolled. Participants will be asked to complete a single research visit, lasting approximately 2 hours, that will include the following procedures: * Participants will be asked to fast for 12 hours prior to arriving. * An IV will be placed for tracer administration * Participants will undergo a research MRI lasting approximately 1.5 hours (up to 1 hour of total scan time) * All participants will be positioned in the MRI scanner for the initial scanning session (30 min) during which the first dose of GBCA (3/4 of total dose) or the total dose of Ferumoxytol will be administered. * 50 participants will be removed from the scanner bore, repositioned, and scanned for an additional 15 minutes (repeatability testing). * All participants will then be removed from the scanner and asked to consume 16 ounces of Ensure Plus®. After 20 minutes, they will be repositioned in the scanner for an additional scanning session (15 min) during which, a second dose of GBCA (1/4 of total dose) will be administered if required.
Study Type
OBSERVATIONAL
Enrollment
146
In-between two MRI exams, patients will ingest a standardized meal of two cans (16oz) of Ensure Plus® (Abbott Laboratories), providing a 700cal meal (13g protein, 11g fat, 50g carbohydrates), proven to elicit a strong hyperemic splanchnic response.
Participants will be asked to complete a single research visit that will include a contrast enhanced MRI scan lasting up to 1 hour. Participants will be asked to fast for at least 5 hours prior to the exam. Participants will be screened a final time for contraindications to contrast enhanced MR imaging; an IV will be placed; and participants will be positioned in the MR scanner, asked to lie as still as possible and to follow some breath hold instructions.
Participants will be screened for any previous reactions to Ferumoxytol or GBCAs and dosing will be consistent with standard of care. Participants will then undergo a research MRI lasting approximately 1.5 hours. * All participants will be positioned in the MRI scanner for the initial scanning session (30 min) during which a 1/2 or 3/4 of the full dose of gadolinium based contrast agent (GBCA) or the total dose of Ferumoxytol will be administered. * The first 50 participants will be removed from the scanner bore, repositioned, and scanned for an additional 15 minutes (repeatability testing). * All participants will then be removed from the scanner and asked to consume 16 ounces of Ensure Plus®. After 20 minutes, they will be repositioned in the scanner for an additional scanning session (15 minutes) during which, the remaining 1/4 or 1/2 dose of GBCA will be administered, if required.
Participants will be asked to complete a single research visit that will include a contrast enhanced MRI scan lasting up to 1.5 hours. Participants will be asked to fast for at least 5 hours prior to the exam. Participants will be screened a final time for contraindications to contrast enhanced MR imaging; an IV will be placed; and participants will be positioned in the MR scanner, asked to lie as still as possible and to follow some breath hold instructions.
University of Wisconsin, Madison
Madison, Wisconsin, United States
RECRUITINGReceiver operation characteristic (ROC) curve analysis to determine diagnostic accuracy
Receiver operation characteristic (ROC) curve analysis will be performed to determine the diagnostic accuracy of 4D flow MRI to differentiate high-risk GEV from absent or low-risk GEV. The area under the curve (AUC) will be estimated for each flow measurement with 95% confidence intervals. The primary analysis is based on fractional flow change in the portal vein.
Time frame: 2 hours
Variation in postprandial flow after Meal Challenge
Variations in flow after a meal will be analyzed under(log-)linear mixed effects (LME) models.
Time frame: pre and post meal (approximately 2 hours)
Repeatability of 4D flow MRI: measured by summary measures of test-retest agreement with 95% Confidence intervals(CIs).
Repeatability of all flow measurements and fractional flow changes will be measured using intra-class correlation coefficient (ICC), and the wishing-subject coefficient of variation (wCV) will be estimated as summary measures of test-retest agreement with 95% CIs.
Time frame: 2 hours
Diagnostic accuracy of 4D Flow MRI to detect high-risk gastroesophageal varices (GEV) compared to esophagogastroduodenoscopy (EGD) as the reference standard
Sensitivity and specificity of fractional flow change in the portal vein (FFCPV) and azygos flow thresholds
Time frame: Baseline
Aspartate aminotransferase-to-platelet ratio index (APRI)
APRI is a way for doctors to measure how healthy a patient's liver is when they have a liver disease. APRI = \[(AST/upper limit of normal)/platelet count\]x100
Time frame: Within 3 months
Fibrosis 4 (FIB-4) index
The Fibrosis-4 score helps to estimate the amount of scarring in the liver. FIB-4 = age (years) × AST \[IU/L\] / \[platelet count × sqr(ALT \[IU/L\])\]
Time frame: Within 3 months
Liver and spleen stiffness measurement by 2D spin-echo MR elastography
2D spin-echo MR elastography will be acquired to assess liver and spleen stiffness, using a single or dual-paddle system to ensure adequate wave-propagation in the liver and spleen
Time frame: Within 3 months
Liver proton density fat fraction (PDFF) as assessed by chemical shift encoded MRI (CSE-MRI)
Liver proton density fat fraction (PDFF) is a biomarker of hepatic steatosis. It will be measured by Chemical shift encoded MRI (CSE-MRI; IDEAL IQ, GE Healthcare),pioneered at UW-Madison. It will help characterizing the possible confounders affecting 4D flow MRI
Time frame: Within 3 months
Hepatic iron level quantitation by in vivo R2* MRI method
R2\* is an imaging method used in MRI. R2\* = (1/T2\*) where R2\* is a relaxation rate measured in units of Hz (\[1/sec\]). R2\* is commonly used to look at iron levels by measuring the relaxation times of hydrogen nuclei affected by iron. The presence of the iron results in the shortening of proton relaxation times (T2\*), thus increasing R2\*. R2\* will be measured by Chemical shift encoded MRI (CSE-MRI; IDEAL IQ, GE Healthcare), pioneered at University of Wisconsin (UW)-Madison. It will help characterizing the possible confounders affecting 4D flow MRI
Time frame: Within 3 months
Child-Turcotte-Pugh (CTP) score for prognosis of cirrhosis
The Child-Turcotte-Pugh (CTP) score is used to assess the severity of cirrhosis. Parameters included are Encephalopathy, Ascites, Bilirubin levels, Albumin levels, Prothrombin Time and International Normalized Ratio (PT/INR) . Parameters are scored on point 1-3. CTP score is obtained by adding the score for each parameter. CTP scores can be categorized into A= 5-6 points, B=7-9 points and C=10-15 points. Higher points correspond to more severe cirrhosis state.
Time frame: Within 3 months
Repeatability of 4D Flow MRI measurements in cirrhotic patients
Intraclass correlation coefficient (ICC) for flow measurements
Time frame: Two hours
Feasibility of radial 4D Flow MRI and meal challenge protocol in FALD patients
Completion rate and image quality scores
Time frame: Two hours
Postprandial mesenteric and portal flow response in FALD vs cirrhosis and healthy controls
Absolute and fractional flow changes in portal and mesenteric vessels
Time frame: pre and post meal (approximately 2 hours)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.