Back pain affects one-third of the UK population every year with a huge impact on the health service and economy. The aim of this study is to test the validity of a computer-vision (CV) technology that uses cameras on phones/tablets/webcams to assess a person's movement and function with the ultimate goal to use the CV system to screen for back pain conditions. Participants with and without back pain will be included in the study and they will be asked to perform standard functional movements that would be used for a physiotherapy assessment for a back condition. The participants will also perform these movements in front of a camera for video recordings to be analysed by the CV system. The measurements by the CV system will be compared to the measurements by the physiotherapist. Additionally, participants will perform and record videos of the same set of movements at home to test the feasibility of the CV system in a home environment.
Back pain affects one-third of the UK population every year with a huge impact on the health service and economy. One specific back pain condition is Axial Spondyloarthropathy (AxSpa), which is an inflammatory spinal arthritis that causes pain and stiffness. This life-long condition presents in the early twenties as 'regular' back pain. Due to its similarity to other back pain conditions, there is an average 8.5-year delay to diagnosis. The aim of this study is to test the validity of a computer-vision (CV) technology that uses cameras on phones/tablets/webcams to assess a person's movement and function with the ultimate goal to use the CV system to screen for back pain conditions, such as AxSpa. The CV system development is led by the GoodBoost Wellbeing Limited and The National Axial Spondyloarthritis Society (NASS) is supporting the recruitment of people living with AxSpa. The CV system that has been developed is a form of artificial intelligence video analysis which is able to automatically measure specific functional movements captured on video. To validate this CV system, this study is designed to compare it to the clinical gold standard measurement by a physiotherapist. Participants with and without back pain will be included in the study and they will be asked to perform standard functional movements that would be used for a physiotherapy assessment for a back condition. The participants will also perform these movements in front of a camera for video recordings to be analysed by the CV system. The measurements by the CV system will be compared to the measurements by the physiotherapist. Additionally, participants will perform and record videos of the same set of movements at home to test the feasibility of the CV system in a home environment.
Study Type
OBSERVATIONAL
Enrollment
100
Oxford Brookes
Oxford, United Kingdom
RECRUITINGPrimary movement Lumbar spine lateral flexion
Concurrent validity of lumbar spine lateral flexion measurement by the CV system compared to physiotherapy measurement.
Time frame: 1 minute
Movement of Lumbar global flexion
Concurrent validity of: Lumbar global flexion measurement by the CV system compared to physiotherapy measurement.
Time frame: 1 minute
Movement of Cervical rotation
Concurrent validity of: Cervical rotation seated measurement by the CV system compared to physiotherapy measurement.
Time frame: 1 minute
Movement of Hip internal rotation
Concurrent validity of: Hip internal rotation seated measurement by the CV system compared to physiotherapy measurement.
Time frame: 1 minute
Movement of Hip abduction
Concurrent validity of: Hip abduction standing measurement by the CV system compared to physiotherapy measurement.
Time frame: 1 minute
Movement of Shoulder flexion
Concurrent validity of: Shoulder flexion measurement by the CV system compared to physiotherapy measurement.
Time frame: 1 minute
Movement 6
Concurrent validity of: Chest expansion measurement by the CV system compared to physiotherapy measurement.
Time frame: 1 minute
Movement of Sit-to-stand
Concurrent validity of Sit-to-stand measurement by the CV system compared to physiotherapy measurement.
Time frame: 1 minute
Standing posture spinal kyphosis
Posture as measured by spinal kyphosis
Time frame: 1 minute
Standing posture tragus to ear
Posture as measured by tragus to walk
Time frame: 1 minute
Leg strength
5 time sit to stand
Time frame: 1 minute