This study aimed to evaluate incidence, prognosis and predictive factors of new-onset of persistent left bundle branch block (LBBB) after rapid-deployment aortic valve replacement (RD-AVR) with the IntuityTM bioprosthesis. It was an observational, retrospective and single-center study. Two hundred and seventy-four consecutive patients without any baseline ventricular conduction disorder or previous permanent pacemaker or defibrillator implantation who underwent RD-AVR with the IntuityTM valve were included. Twelve-lead electrocardiogram and transthoracic echocardiography were performed preoperatively, postoperatively, at discharge, 1-month, and 1-year. Incidence, prognosis and predictive factors of new-onset of persistent LBBB were evaluated.
Study Type
OBSERVATIONAL
Enrollment
274
Assistance Publique Hôpitaux de Marseille
Marseille, France
Incidence of NOP-LBBB (new onset of persistent left bundle branch block)
QRS duration ≥ 120 ms with QS or rS patterns on the V1 lead, a large notched R wave in D1, aVL, V5 and V6 and the absence of Q wave in V5 and V6, according to the recommendations of the American Heart Association. NOP-LBBB was persistence of LBBB on the 12-lead recording electrocardiogram (ECG) at discharge from hospital.
Time frame: at 1 year