The goal of this study is to test a new way to diagnose and track treatment of spine infections caused by the bacteria Staphylococcus aureus.
Ongoing Staphylococcus aureus (S. aureus) infections of the spine associated with orthopedic hardware implants elicit prominent immune responses against a repertoire of proteins characteristic of the invading pathogen. Antibodies specific for these antigens can be measured in the serum or in a novel sample created by culturing circulating Antibody Secreting Cells (ASC) in vitro where they create an analytic fluid called here "medium enriched for newly synthesized antibodies" (MENSA). The hypothesis of this study addresses three essential attributes of this analytic approach that can yield both a valuable tool for research on spinal infections and in the future, this can be developed a clinical tool for diagnosis and monitoring of therapeutic success in patients. By measuring the emergence of these signature antibodies in the serum and/or MENSA, the goals of this study are: 1) To differentiate between patients with an ongoing S. aureus infections, not just "general infection, in the spine using only blood samples; 2) To track the success (or failure) of therapeutic interventions; and 3) to distinguish spinal infections from S. aureus infections in other sites by the repertoire of antibodies that are elicited.
Study Type
OBSERVATIONAL
Enrollment
200
Medium enriched for newly synthesized antibodies titers in patients with Staphylococcus aureus infections of orthopedic spine implants at baseline and in the post operative period
Univeristy of Colorado Denver
Aurora, Colorado, United States
The percentage of Staphylococcus aureus spine implant associated infections correctly identified by "medium enriched for newly synthesized antibodies" (MENSA)
"A medium enriched for newly synthesized antibodies" (MENSA) is the supernatant collected from cultured antibody secreting cells. Peripheral blood monocytes (PBMCs) are washed and placed into cell culture. After 24 hours, the media contains a high concentration of newly made antibodies. This media is referred to as MENSA. This is tested to see if the antibodies collected react against a panel of antigens. MENSA immunoglobulin G (IgG) titers for each antigen will be assessed for their predictive ability to identify the presence of S. aureus in spine implant-associated infections using receiver operating characteristic (ROC) curve analysis (alone or in combination), with overall prediction accuracy summarized by the area-under-the-curve (AUC). Participants will then be categorized as Staphylococcus aureus (S. aureus) positive or negative based on MENSA. The percentage of correctly identified S. aureus determinations compared to clinical diagnosis will be determined.
Time frame: Baseline
Change "Medium enriched for newly synthesized antibodies" (MENSA) titers in the post-operative period
MENSA IgG titers (as defined in Outcome 1) will be measured at 2 weeks, 6 weeks, 3 months, 6 months, 1 year and 2 years post-surgery. A longitudinal measure of antibody activity defined as the average change per study visit from baseline will used to track infection clearance versus persistent infection. Levels of anti-S. aureus antibodies in MENSA should decline to background in patients whose infections have been successfully treated and remain elevated in those whose infections persist.
Time frame: 2 weeks, 6 weeks, 3 months, 6 months, 1 year and 2 years post-surgery
"Medium enriched for newly synthesized antibodies" (MENSA) titers in spine implant infections compared to S. aureus infections of other orthopedic site infections.
MENSA IgG titers (as defined in Outcome 1) will be compared to responses measured in a pre-existing collection of samples from patients who had experienced: 1) prosthetic joint infections; 2) septic arthritis; 3) diabetic foot infections; 4) soft-tissue infections; and 5) fracture-related infections. The goal will be to identify a combination of antigens that is uniquely discriminatory for spine infections.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: Baseline
Confirmation of Staphylococcus aureus in spine implant associated infection by polymerase chain reaction (PCR)
Total DNA will be collected from surgical discarded tissue from sites adjacent to the infection. polymerase chain reaction (PCR) using primers that amplify a region of the Staphylococcus aureus genome will be run to confirm the presence/absence of Staphylococcus aureus at the infection site.
Time frame: Baseline