Transradial approach has become the default arterial access for coronary angiography (CAG) and percutaneous coronary intervention (PCI), mainly due to lower incidence of bleeding compared to transfemoral access.1 However, TRA is not deprived of local access site complications such as radial artery occlusion (RAO), occurring in approximately 5.2% of patients, compartment syndrome, pseudoaneurysm, hematoma, and arteriovenous fistula. Recently, a novel approach has been proposed, the access through the distal radial artery (distal transradial access, dTRA), located in the anatomical snuffbox. Initial studies regarding the dRA have shown feasibility and benefits, including shorter hemostasis time, fewer local access site complications and potentially lower incidence of RAO. GlideSheath Slender is a novel sheath which has a hydrophilic coating and is made of a thinner material than traditional sheaths. As a result, the external diameter of the 5 Fr GlideSheath Slender sheath is 1 Fr lower compared with conventional arterial sheaths. The purpose of the present study was to investigate whether the use of the Slender sheath affects the time of hemostasis, sheath insertion time, crossover rate to conventional radial access, pain associated with the procedure and incidence of local access site complications (RAO, distal radial artery occlusion, fistula, hematoma) in patients undergoing diagnostic angiography through the distal radial artery.
Patients fulfilling the enrollment criteria will be randomized 1:1 to GlideSheath Slender versus conventional 5Fr arterial sheath for access through the distal radial artery (dTRA). In case an interventional procedure is required then the initial sheath will be exchanged to a larger sheath according to the circumstances of the case and the patient will not be included in the analysis. For randomized patients sheath insertion time, necessity for crossover to conventional radial access, pain associated with the procedure (visual pain scale) and occurrence of hematoma will be recorded. Follow-up ultrasound 7-10 days after the procedure for detection of RAO, distal radial artery occlusion and fistula formation will be performed.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
SINGLE
Enrollment
371
Placement of GlideSheath Slender 5Fr arterial sheath for coronary angiography through the distal radial artery (anatomical snuffbox).
Placement of conventional 5Fr arterial sheath for coronary angiography through the distal radial artery (anatomical snuffbox).
University Hospital of Patras
Pátrai, Achaia, Greece
Rate of successful hemostasis at 30 minutes after sheath removal
Time frame: At 30 minutes after sheath removal
Crossover rate to conventional radial access
Time frame: During the procedure
Pain associated with the procedure (visual analog scale, VAS)
0-10, 0: no pain, 10: worst pain possible
Time frame: During the procedure
Rate of hematoma modified EASY class≥II
Time frame: Up to 24 hours after hemostatic device removal
Rate of forearm radial artery occlusion
Time frame: 7-10 days after the coronary angiography
Rate of distal radial artery occlusion
Time frame: 7-10 days after the coronary angiography
Rate of fistula formation
Time frame: 7-10 days after the coronary angiography
Rate of pseudoaneurysm formation
Time frame: 7-10 days after the coronary angiography
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.