In this study,the AI-assisted system(EndoAngel)has the functions of reminding the ileocecal junction, withdrawal time, withdrawal speed, sliding lens, polyps in the field of vision, etc. These functions can improve the colonoscopy performance of novice physicians and assist the colonoscopy training。
Colonoscopy is a key technique for detecting and diagnosing lesions of the lower digestive tract.High-quality endoscopy leads to better disease outcomes.However, the demand for endoscopy is high in China, and endoscopy is in short supply.A colonoscopy is a complex technical procedure that requires training and experience for maximal accuracy and safety.Therefore, it is of great significance to improve the colonoscopy ability of novice physicians and shorten the colonoscopy training time for solving the problems such as the lack and uneven distribution of digestive endoscopists and the substandard quality of endoscopy in China. In recent years, deep learning algorithms have been continuously developed and increasingly mature.They have been gradually applied to the medical field. Computer vision is a science that studies how to make machines "see". Through deep learning, camera and computer can replace human eyes to carry out machine vision such as target recognition, tracking and measurement.Interdisciplinary cooperation in the field of medical imaging and computer vision is also one of the research hotspots in recent years. At present, it is mainly applied to the automatic identification and detection of lesions and quality control, and has achieved good results. Our preliminary experiments have shown that deep learning has a high accuracy in endoscopic quality monitoring, which can effectively regulate doctors' operations, reduce blind spots and improve the quality of endoscopic examination.At the same time, it can also monitor the doctor's withdrawal time in real time and improve the detection rate of adenoma.In the previous work of our research group, we have successfully developed deep learning-based colonoscopy withdraw speed monitoring and intestinal cleanliness assessment, and verified the effectiveness of the AI-assisted system(EndoAngel) in improving the quality of gastroscopy and colonoscopy in clinical trials. Based on the above rich foundation of preliminary work, as well as the huge demand in the field of colonoscopy training,By comparing the colonoscopy operation training for novices with and without EndoAngel assistance, we plan to compare the colonoscopy learning effect of novices with and without assistance, including skill results and cognitive level, to explore whether AI can promote the improvement of the colonoscopy operation training for novices.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
DOUBLE
Enrollment
385
the artificial intelligence assistance system can indicate abnormal lesions and real-time withdrawal speed, and feedback the overspeed percentage.
Renmin hospital of Wuhan University
Wuhan, Hubei, China
RECRUITINGCUSUM learning curve for colonoscopy (ACE scoring scale)
Time frame: From the beginning to the end of colonoscopy training
Average test score difference before and after training
Time frame: From the beginning to the end of colonoscopy training
Detection rate of advanced adenoma
The numerator is the number of patients diagnosed with advanced adenomas, and the denominator is the total number of patients undergoing colonoscopy,Advanced adenoma was defined as \> 10mm adenoma, villous adenoma, tubular villous adenoma, high-grade intraepithelial neoplasia, and carcinoma.
Time frame: A month
Polyp Detection Rate, PDR
The numerator is the number of patients with polyps detected by colonoscopy, and the denominator is the total number of patients who underwent colonoscopy
Time frame: A month
Average number of adenomas detected per patient
The numerator is the total number of adenomas detected by colonoscopy, and the denominator is the total number of patients undergoing colonoscopy.
Time frame: A month
The detection rate of large, small and micro polyps
The numerator is the number of patients with large (≥10 mm), small (6-9 mm) and micro-small (≤5 mm) polyps detected by colonoscopy, and the denominator is the total number of patients receiving colonoscopy.
Time frame: A month
The average number of large, small and micro polyps detected
The numerator is the total number of large (≥10 mm), small (6-9 mm) and micro-small (≤5 mm) polyps detected by colonoscopy, and denominator is the total number of patients undergoing colonoscopy.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: A month
The detection rate of large, small and micro adenomas
The numerator is the number of patients with large (≥10 mm), small (6-9 mm) and micro-small (≤5 mm) adenomas detected by colonoscopy, and the denominator is the total number of patients receiving colonoscopy.
Time frame: A month
The average number of large, small and micro adenomas detected
The numerator is the total number of large (≥10 mm), small (6-9 mm) and micro-small (≤5 mm) adenomas detected by colonoscopy, and denominator is the total number of patients undergoing colonoscopy.
Time frame: A month
The detection rate of adenoma in different sites
The numerator is the number of patients with adenomas detected in the rectum, sigmoid colon, descending colon, transverse colon, ascending colon, ileocecal region and other sites during colonoscopy, and the denominator is the total number of patients receiving colonoscopy.
Time frame: A month
The average number of adenomas detected in different sites
The numerator is the total number of adenomas detected in the rectum, sigmoid colon, descending colon, transverse colon, ascending colon, ileocecal region and other sites during colonoscopy, and the denominator is the total number of patients undergoing colonoscopy.
Time frame: A month
Number of missed return of the sliding endoscopy/number of successful return of the sliding endoscopy
The numerator is the total number of sliding endoscopy during colonoscopy, and the denominator is the number of sliding endoscopy and successful return endoscopy during colonoscopy
Time frame: A month
Real-time gut cleanliness score
During colonoscopy, a real-time intestinal cleanliness score was given by EndoAngel based on the Boston-scale Boreal Preparation Score (BBPS).
Time frame: During procedure
withdraw overspeed percentage
The ratio of the overspeed duration to the total duration in the process of withdrawal.
Time frame: During procedure
The withdraw time
The time between colonoscopy arrival at ileocecal valve and colonoscopy exit from anus.
Time frame: During procedure
Ratio of ileocecal reach
For a period of time, the number of colonoscopies that failed to reach the ileocecal part accounted for the proportion of the total number of colonoscopies.
Time frame: A month