The cemented femoral stem have impact on increase on systemic parameters. Evaluation of the level of histamine, C-reactive protein (CRP) and leukocytes formula, IL1b, TNF alpha, IL6 and the reflection of changes of these parameters in the intra-operative course of hip replacement.
Implantation of total endoprosthesis is a very common surgical procedure and is performed with and without bone cement. In most cases during cementation of the femoral component there are changes in blood pressure, SpO2, heartbeat and other vital parameters which can cause complications during surgery. Comparing the system parameters between the two groups and deriving these results will help the medical staff to be more professionally prepared to resolve possible complications.
Study Type
OBSERVATIONAL
Enrollment
60
The hip replacement surgery is when a damaged hip is replaced with artificial one
University Clinical Center of Kosovo
Pristina, Kosovo
RECRUITINGChange of systemic parameters during and after hip replacement (Histamine)
Analysis of the impact of cement in different laboratory parameters such as histamine
Time frame: The measurement of these laboratory parameters 5 minutes before and 10 minutes after surgical procedures will reflect the impact of cements in the eventual post-surgical complications, such are embolism and other complications.
Change of systemic parameters during and after hip replacement (CRP)
Analysis of the impact of cement in different laboratory parameters such as C-reactive protein (CRP)
Time frame: The measurement of these laboratory parameters 5 minutes before and 10 minutes after surgical procedures will reflect the impact of cements in the eventual post-surgical complications, such are embolism and other complications.
Change of systemic parameters during and after hip replacement (Leukocytes formula)
Analysis of the impact of cement in different laboratory parameters such as changes of leukocytes formula
Time frame: The measurement of these laboratory parameters 5 minutes before and 10 minutes after surgical procedures will reflect the impact of cements in the eventual post-surgical complications, such are embolism and other complications.
Change of systemic parameters during and after hip replacement (IL1b)
Analysis of the impact of cement in different laboratory parameters such as IL1b
Time frame: The measurement of these laboratory parameters 5 minutes before and 10 minutes after surgical procedures will reflect the impact of cements in the eventual post-surgical complications, such are embolism and other complications.
Change of systemic parameters during and after hip replacement (TNF alpha)
Analysis of the impact of cement in different laboratory parameters such are TNF alpha
Time frame: The measurement of these laboratory parameters 5 minutes before and 10 minutes after surgical procedures will reflect the impact of cements in the eventual post-surgical complications, such are embolism and other complications.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Change of systemic parameters during and after hip replacement (IL6)
Analysis of the impact of cement in different laboratory parameters such as IL6.
Time frame: The measurement of these laboratory parameters 5 minutes before and 10 minutes after surgical procedures will reflect the impact of cements in the eventual post-surgical complications, such are embolism and other complications.
Difference of arterial pressure
Difference of arterial pressure after implantation of femoral component
Time frame: The changes will be measured 5 minutes before implantation and during first 10 minutes after implantation
Difference of changes of Leukocyte formula
Difference of changes of Leukocyte formula after implantation of femoral component
Time frame: The blood will be taken from patience 1 hour before and Post Operative Day One
Difference of SpO2
Difference of SpO2 after implantation of femoral component The changes will be measured by the device monitor connected to patient
Time frame: The changes will be measured 5 minutes before implantation and during first 10 minutes after implantation]