In the previous studies, EUS-guided fine needle aspiration (FNA) with fanning technique in solid pancreatic lesions (SPLs) with avascular areas had a negative impact on diagnostic accuracy of FNA. Because of the retrospective basis of previous studies, a prospective study is warranted to answer whether contrast-enhanced harmonic(CEH) EUS-guided FNA/B is superior to conventional EUS-guided FNA/B with fanning technique in SPLs. The main objective of this randomized trial therefore was to determine whether CEH-EUS-guided sampling to avoid non-enhanced areas within a mass lesion result in more rapid diagnosis requiring fewer FNB passes than the conventional EUS-guided FNB with fanning needle throughout the mass is targeted.
A prospective randomized controlled study was undertaken of patients with solid pancreatic mass lesions who were referred for EUS. Total 120 patients were randomized with 1:1 ratio into undergo CEH-EUS-guided FNB or conventional EUS-guided FNB with fanning technique. At the time of the procedure, the endoscopy nurse opened an envelope containing computer-generated randomization assignments for the study patients. All procedures were performed by a linear array echoendoscope (Olympus UCT260; Olympus, Tokyo, Japan). Procedures were performed under conscious sedation with patients in the left lateral decubitus position. In CEH-EUS-guided FNB group, needle puncture directly to the enhancing area 15-20 times without passing to the non-enhancing area was performed. In conventional-EUS-guided FNB with fanning technique group, the needle was positioned at four different areas within the mass and then moved back and forth four times in each area to procure tissue (4 × 4). After each pass, the needle is removed and the stylet will be introduced into the needle to extrude any aspirated material on a glass slide for inspection of the presence of a macroscopic visible core (MVC). The total length of the MVC will be measured before placement into a formalin bottle. EUS-FNB is completed if the obtained MVC is longer than 4mm and deemed adequate by endoscopist. If the obtained MVC is \< 4mm, the procedure is repeated until a MVC of ≥ 4mm is obtained and deemed adequate by endoscopist. A maximum of 7 passes is allowed.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
DOUBLE
Enrollment
120
Under endoscopic ultrasound guidance, fine-needle biopsy is used to collect biopsy samples from solid pancreatic lesions throughout the digestive tract and is useful in diagnosing solid pancreatic lesions.
National Taiwan University Hospital
Taipei, Taiwan
RECRUITINGthe median number of passes required to establish a diagnosis
EUS-FNB is completed if the obtained macroscopic visible core (MVC) is longer than 4mm and deemed adequate by endoscopist
Time frame: 1 day
diagnostic accuracy rate
Diagnostic accuracy was defined as the proportion of patients in whom successful diagnosis was reached within the procedure
Time frame: 3 months
overall complication rate
Time frame: 3 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.