In Canada, the incidence of esophageal cancer has been increasing over time, while surgical standards for esophageal resections have remained unchanged. Currently, the standard of surgical care for this cancer is Open Transthoracic Esophagectomy (OTE), a highly morbid operation that is associated with a complication rate of 60-80%, and a recovery period of many months. While Minimally Invasive Esophagectomy (MIE) has been developed it has not been adopted because it is highly complex, technically demanding, and has a longer operative time than OTE. With the advent of robotic platforms, Robotic Assisted Minimally Invasive Esophagectomy (RAMIE) has recently emerged as a novel minimally invasive alternative to OTE. RAMIE utilizes the DaVinci Xi robotic surgical platform which offers superior dexterity, 3D-vision, and wristed surgical equipment. To date, case reports and small case series have demonstrated the safety of RAMIE, however it has not been performed yet in Canada, and there has been no randomized trial that has compared RAMIE to OTE. This study proposes to build the infrastructure for introducing RAMIE to Canada, while laying the foundations for a future randomized controlled trial which will compare it to OTE.
In Canada, the incidence of esophageal cancer has been increasing over time. The treatment of patients with cancer of the esophagus is multi-modal, with surgery being the cornerstone of most treatment regimens. Operative treatment is usually performed through Open Transthoracic Esophagectomy (OTE), a highly morbid procedure that is associated with a complication rate of 60-80%, and a recovery period of many months. This standard is being challenged by a growing body of evidence demonstrating that a minimally invasive approach can reduce post-operative morbidity and improve quality-of-life, while still offering an adequate oncological outcome. The minimally invasive alternative to OTE is Minimally Invasive Esophagectomy (MIE). Although MIE has been shown to reduce the morbidity associated with esophagectomy, it has not been widely adopted. This failure of adoption is due to the high complexity of MIE; it is an exceedingly difficult operation, is associated with a very steep learning curve, and can take 8-10 hours to complete. As a result, less than 10% of esophageal cancer programs in Canada have adopted MIE, and there remains a need for a minimally invasive alternative to OTE. Robotic Assisted Minimally Invasive Esophagectomy (RAMIE) has recently emerged as a minimally invasive alternative to OTE. RAMIE utilizes the DaVinci Xi robotic surgical platform which offers superior dexterity, 3D-vision, 7-degrees of freedom for range of motion, and near-infrared imaging for detection of blood vessels. As a result, RAMIE has succeeded where MIE has failed, and has been widely taken up in Europe and the United States. To date, near-infrared fluorescence (NIF)-guided RAMIE using indocyanine green (ICG) dye has not been performed in Canada, and there has been no randomized trial that has compared NIF-guided RAMIE using ICG dye to OTE. In this study, we propose to build the infrastructure for introducing NIF-guided RAMIE using ICG dye to Canada, while laying the foundations for a future randomized controlled trial (RCT) which will compare it to OTE. This study is a Phase I, single center, prospective feasibility randomized controlled trial with two phases: Phase A: Learning Curve of NIF-guided RAMIE using ICG dye; and Phase B: A Randomized Controlled Feasibility Trial. In Phase A, 40 patients will be enrolled, and they will all undergo NIF-guided RAMIE using ICG dye. Evidence shows that a surgeon experienced in MIE requires experience of 40 cases to gain proficiency of RAMIE. In Phase B, 54 patients will be enrolled, and they will be randomized to either NIF-guided RAMIE using ICG dye, or OTE.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
24
Robotic Assisted Minimally Invasive Esophagectomy (RAMIE) will be performed using the Da Vinci Robotic Surgical Platform.
Open Transthoracic Esophagectomy (OTE) is the current standard of care.
Robotic Assisted Minimally Invasive Esophagectomy (RAMIE) will be performed using the Da Vinci Robotic Surgical Platform.
St. Joseph's Healthcare Hamilton
Hamilton, Ontario, Canada
The feasibility of a large-scale RCT, as measured by the number of patients willing to participate in the study.
A recruitment rate ≥70%, whereby participants partake in the study until first post-operative follow-up, would be considered acceptable.
Time frame: 3-Weeks Postoperative
Safety of the Operation, based on rates of perioperative complications
The safety of the operation based on rates of perioperative complications within 90-days of surgery, as defined by the Ottawa Thoracic Morbidity and Mortality Classification System (TMNM).
Time frame: 12-Weeks Postoperative
Patient-Reported Health-Related Quality of Life - Pain Level
The Stanford Pain Scale will be administered to patients to assess pain (0 = no pain, 10 = worst pain)
Time frame: Baseline, Postoperative Day 1, 3-Weeks Postoperative, 12-Weeks Postoperative
Patient-Reported Health-Related Quality of Life - Quality of Life
EQ-5D-5L will be administered to patients to assess pain and quality of life. 5 items + overall health rating (0-100; 0 worst health imaginable, 100 best health imaginable)
Time frame: Baseline, Postoperative Day 1, 3-Weeks Postoperative, 12-Weeks Postoperative
Patient-Reported Health-Related Quality of Life - Reintegration into Normal Living
Reintegration to Normal Living Index will be administered to patients to assess quality of life. 11 items, each item scored from 1-10 (1 = no reintegration, 10 = complete reintegration)
Time frame: Baseline, Postoperative Day 1, 3-Weeks Postoperative, 12-Weeks Postoperative
Conversion from RAMIE to OTE
Rate of conversions from RAMIE to OTE
Time frame: During Surgery
Length of Stay (LOS)
Length of hospital stay will be measured between the date of admission and date of discharge.
Time frame: From Date of Admission to Date of Discharge, assessed up to 12-Weeks Postoperative
Length of Operation
Operative time will be measured by collecting the procedure start and procedure end time
Time frame: During Surgery