1\. Compare the effect of virtual single energy imaging and virtual single energy combined with MAR technology to remove metal artifacts in the spine. 2. Discuss the most suitable KeV of virtual single energy imaging combined with MAR technology to remove metal artifacts.
The virtual single-energy imaging of energy spectrum CT combined with the metal artifact reduction technology MARS Multi Artifact Reduction System\] can effectively reduce the interference of metal artifacts. This is because MAR technology corrects the image through an iterative algorithm, improves the spatial resolution, and restores the details of the adjacent tissue of the metal object. Virtual single-energy imaging technology can effectively reduce hardening artifacts. The two are used in combination to achieve the purpose of reducing metal artifacts. There have been articles about virtual single energy combined with MAR technology to reduce metal artifacts. However, the current researches mostly focus on the comparison of virtual single energy combined with MAR technology and conventional CT examination and virtual single energy imaging. There are few evaluations on the severity of metal artifacts after spinal surgery. According to different surgical methods, metal The difference in the number of implants will result in different artifact reduction effects. Secondly, the current research on the suitable KeV of virtual single energy combined with MAR technology to reduce metal artifacts is less discussed and reported.
Study Type
OBSERVATIONAL
Enrollment
43
combined with MAR reconstruction group
Peking University Third Hospital
Beijing, Beijing Municipality, China
Artifact Index
Select the largest level of artifacts in the image, place a region of interest (ROI) with an area of 100-150mm2 in the soft tissue around the metal and spinal canal for CT value and standard deviation (SD) measurement, avoid the boundary area, and measure the ROI area Artifact Index ASelect the largest level of artifacts in the image, place a region of interest (ROI) with an area of 100-150mm2 in the soft tissue around the metal and spinal canal for CT value and standard deviation (SD) measurement, avoid the boundary area, and measure the ROI area Artifact Index AI
Time frame: 2019.2.1-2019.2.15
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.