How to maintain the stability of circulation during anesthesia has always been a concern of clinicians, including shorting the preoperative fasting time under the condition of full preoperative preparation, and giving appropriate amount of nutrient solution in combination with the patient's situation 2\~4 h before surgery to reduce the blood volume insufficiency of patients before general anesthesia induction, vasoactive drugs, etc. Among them, passive leg lifting experiment is widely recognized in the world. Although passive leg lifting has many advantages, it still has some limitations in the operation process. This study tried to find the corresponding head low and foot high Angle corresponding to the same hemodynamic changes caused by passive leg lifting.
For low head and high feet, studies have shown that 20° can reduce the incidence of hypotension during the induction period of general anesthesia in patients undergoing gastrectomy and has therapeutic effect on it, as well as reduce the use of vasoactive drugs during the induction period of general anesthesia. There were no perioperative complications. The passive leg lift test can be repeated and does not overload the patient with fluid. However, there is no relevant research on the relationship between the two, which is exactly the innovation of this topic.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
54
Use a -5 or -10 or -15 degree trendelenburg position
The Second Affiliated Hospital of Dalian Medical University
Dalian, Liaoning, China
RECRUITINGPPV(pulse pressure variation)
Change from PPV at T1to T6
Time frame: T1:A supine position with a 10° upward bed angulation;T2: After passive leg lift;T3:The same position with T1;T4:After trendelenburg position;T5:The same position with T1;T6:After fluid infusion
VTI(velocity time integral)
Change from VTI at T1 to T6
Time frame: T1:A supine position with a 10° upward bed angulation;T2: After passive leg lift;T3:The same position with T1;T4:After trendelenburg position;T5:The same position with T1;T6:After fluid infusion
SBP(Systolic Blood Pressure)
The variation tendency of T1 to T6
Time frame: T1:A supine position with a 10° upward bed angulation;T2: After passive leg lift;T3:The same position with T1;T4:After trendelenburg position;T5:The same position with T1;T6:After fluid infusion
MAP(Mean Artery Pressure)
The variation tendency of T1 to T6
Time frame: T1:A supine position with a 10° upward bed angulation;T2: After passive leg lift;T3:The same position with T1;T4:After trendelenburg position;T5:The same position with T1;T6:After fluid infusion
HR HR(Heart Rate)
The variation tendency of T1 to T6
Time frame: T1:A supine position with a 10° upward bed angulation;T2: After passive leg lift;T3:The same position with T1;T4:After trendelenburg position;T5:The same position with T1;T6:After fluid infusion
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.