Study to assess the capability of physicians (breast surgeons and pathologists) to recognize breast cancer in images of fresh lumpectomies generated with the Histolog Scanner, a recent large field-of-view confocal laser scanning medical imaging device.
Breast cancer is the commonest cancer in female worldwide and breast-conserving surgery (BCS) became the most frequently performed surgical treatment for women with early-stage breast cancer. The ability to identify subclinical and deep-seated tumor during BCS is still difficult, and the surgeon must rely on nonspecific visual changes and manual palpation of subtle irregularities to guide cancer excision. Although there is no consensus on negative surgical margins, at least 20 % of patients undergo more than one procedure to achieve acceptable margins as part of breast-conserving strategy. The development of reliable intraoperative assessment tools which can provide a timely indication of whether re-excision in tumor bed after BCS is indicated at the time of primary surgery would be an asset. The Histolog Scanner is a recent confocal microscope designed for fresh tissue ex-vivo medical imaging with high resolution and speed to guide intraoperative assessment and offer support in clinical decision making. Allowing the quickest and most effective intraoperative assessment of breast surgical specimen regardless of center clinical workflow and intraoperative availability of pathologist, is the aim of this international study. The main objective is to demonstrate that both pathologists and surgeons are able to detect breast cancer tissues in Histolog Scanner images of breast surgical specimens. Fresh Breast surgical specimens with breast cancer (invasive or in-situ) will be imaged with the Histolog Scanner prior Standard-of-Care final assessment in pathology. Content of the images will be reviewed by a board of expert pathologists using the gold standard (H\&E-stained images) as reference. Blind assessment of the breast cancer content of these Histolog Scanner images will be realized by breast surgeons and pathologist.
Study Type
OBSERVATIONAL
Enrollment
181
imaging of fresh lumpectomy specimens with the Histolog Scanner, confocal microscopy scanning medical imaging device
Institut Gustave Roussy
Villejuif, France
Accuracy, Sensitivity, Specificity, Positive predictive value, Negative predictive value for breast cancer detection
Quantification of the performance achieved by breast surgeons and pathologists for breast cancer detection in Histolog Scanner images
Time frame: Through study completion, an average of 1 year
Accuracy for breast cancer diagnosis
Quatification of the performance achieved by pathologists to differentiate breast cancer subtype (IDC, DCIS or ILC) in Histolog scanner images.
Time frame: Through study completion, an average of 1 year