Purpose of the research; To determine the effects of wearable technology follow-up, breathing exercises with a breathing exercise device and reading aloud on vital signs, fatigue and respiratory function parameters in individuals with COPD. This research will be conducted using a randomized controlled trial model. "Personal Description Form", "COPD and Asthma Fatigue Scale", Visual Analog Scale and pulmonary function tests will be used in data collection.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
NONE
Enrollment
131
The breathing exercise device is a device that simulates pursed-lip breathing by creating positive expiratory pressure (PEP). Before starting to use the device, it will be explained that they need to put the mouthpiece on the device and put the nose clip on their nose, and the participants will be shown how it is done. The device will be used at 5 cmH2O pressure. A single exercise session consists of 3 exercise cycles, and a single exercise cycle consists of 15 breathing-exhalation activities. Participants will complete 3 cycles (a total of 45 inhales and exhales) in a single session. 1 loop lying on the left side, 1 loop lying on the right side, and 1 loop in sitting upright position. Participants held these sessions in the morning, afternoon, and evening. After completing each cycle, the participants will remove their nose clips and cough 2-3 times. Each participant will perform a total of 135 breathing exercises in one day.
The patients in this group were given a book that they chose from among the book types within the scope of the study, according to their wishes. For the selection of books, opinions were taken from the experts in the education faculty of the same university and it was stated that any book separation was not important. The books that the participants wanted to read were provided by the researcher. They were asked to read this book aloud during the day, sitting upright on a chair or sofa, for 15 minutes, three times a day. They were able to stop reading when the participant was tired or felt too short of breath to continue reading.
İnönü University
Malatya, Turkey (Türkiye)
Pulmonary Function Parameters
Change in FEV1/FVC ratio will be evaluated with pulmonary function test
Time frame: 2 month
Fatigue
The COPD and Asthma Fatigue Scale was developed by Revicki et al in 2010 to reveal the effect of COPD and Asthma on fatigue. The items of the questions in the scale, which consists of 12 questions in total, are graded with a 5-point Likert type as "never", "rarely", "sometimes", "often", "very often". A total of 12 to 60 points is obtained from the scale. A single score is obtained from the scale for the state of fatigue, and there is no evaluation of the sub-dimensions. An increase in this score indicates that the person's fatigue level is high.
Time frame: 2 month