The purpose of this project is to evaluate the efficacy of oxygen insufflation (continuous oxygen flow) to keep oxygen saturation (oxygen levels measured with a pulse oximeter \[finger device used in medicine\]) at 90% or greater in adult patients undergoing microlaryngoscopy surgery.
High flow, low pressure oxygen will be supplied in microlaryngoscopy airway surgery. These procedures are usually performed with jet ventilation (UAB) or intermittent apnea (surgery centers). Jet ventilation provides oxygenation with limited ventilation but come with high risks, such as barotrauma, pneumothorax, mucosa drying, and even death in the most severe cases. Intermittent apnea is a nuisance for the surgeon in that surgical time is often interrupted with having to place the endotracheal tube whenever the patient's oxygen saturation levels fall. The solution is oxygen insufflation, which will give extended oxygenation times for the surgeon to operate without the inherent risks associated with jet ventilation. During the procedure, oxygen tubing will be connected to the surgeon's laryngoscope instead of the jet ventilation tubing. Oxygen flows of 15 L/min will be administered through the laryngoscope to the posterior oropharynx. Endotracheal tube will be placed if oxygenation deemed insufficient due to oxygen saturations of \<90%. Endotracheal tube will be intermittently placed to check and correct carbon dioxide levels.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DEVICE_FEASIBILITY
Masking
NONE
high flow, low pressure oxygen with pressure relief valve and luer Lock connections delivered at 15 L/min through surgeon's laryngoscope.
High flow, low pressure oxygen can increase apneic oxygenation time during airway procedures
15 liters per minute of oxygen will be administered to the posterior oropharynx.
Time frame: 30-60 minutes
Degree of hypercapnia experienced by participants
Measurement will be taken by intermittent ventilation by placing an endotracheal tube
Time frame: 30-60 minutes
Participants That Maintain Adequate Oxygenation at 90% or Greater
Pulse oximetry will be used to measure oxygenation status
Time frame: 30-60 minutes