Prospective, single-arm, multi-center study to evaluate safety and effectiveness of the Autus Size-Adjustable Valve in pediatric patients aged 18 months to 16 years requiring surgical pulmonary valve replacement. The Autus Valve may be expanded pre-implant to match the subject's body size. Subjects will be evaluated prior to the Autus Valve implant procedure, immediately post-implant, at hospital discharge, 30 days, 6 months, and annually through 10 years. The Autus Valve may be expanded post-implant via transcatheter balloon dilation to accommodate growth of the subject. In subjects who undergo a post-implant valve expansion, follow-up will continue for a minimum of 1 year after the post-implant valve expansion procedure.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
51
Pulmonary valve replacement surgery with the Autus Valve
Children's Hospital Los Angeles
Los Angeles, California, United States
Children's Hospital Colorado
Aurora, Colorado, United States
Children's Healthcare of Atlanta
Atlanta, Georgia, United States
Ann and Robert H. Lurie Children's Hospital of Chicago
Chicago, Illinois, United States
Boston Children's Hospital
Boston, Massachusetts, United States
University of Michigan - Mott Children's Hospital
Ann Arbor, Michigan, United States
Columbia University Irving Medical Center/New York Presbyterian Morgan Stanley Children's Hospital
New York, New York, United States
Duke University
Durham, North Carolina, United States
Nationwide Children's Hospital
Columbus, Ohio, United States
Children's Hospital of Philadelphia
Philadelphia, Pennsylvania, United States
...and 2 more locations
Valve Implantation Primary Safety Endpoint
Composite Endpoint: Freedom from a device-related complication through 30 days post-valve implantation as adjudicated by an independent Clinical Events Committee (CEC), including: * Death; * Valve thrombosis requiring intervention; * Symptomatic thromboembolism.
Time frame: 30 Days post-valve implantation
Valve Implantation Primary Effectiveness Endpoint
Acceptable hemodynamic performance at 6 months post-valve implantation, as assessed by the Echocardiography Core Laboratory or Clinical Events Committee, defined as: * A mean RVOT gradient less than or equal to 40 mmHg and * Less than moderate pulmonary regurgitation by transthoracic echo and * No Autus Valve reintervention except for valve expansion to address prosthesis-patient mismatch.
Time frame: 6 Months post-valve implantation
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.