Hypoxemic acute respiratory failure is one of the main COVID-19 patients complication that lead to in intensive care hospitalization. This complication determines a variable mortality from 25 to 30%. To correct hypoxemia (often severe) is often needed non-invasive or invasive mechanical ventilation. Mechanical ventilation is not a therapeutic strategy, but it allows to extend the time-to-recovery necessary to solve COVID-19 respiratory failure cause. Calibration of ventilatory support is essential to ensure adequate time-to-recovery without contributing to onset lung and / or diaphragmatic damage. Basal diaphragmatic activity assessment, device for administering the oxygenation support choice and setting ventilatory support parameters are decisive. Ultrasound is the best method for measuring diaphragmatic work. The aim of this study is to evaluate the diaphragmatic thickening fraction in COVID-19 patients admitted to Intensive Care Unit (ICU) for acute respiratory failure and to record its function on weaning.
Hypoxemic acute respiratory failure in COVID-19 patients often leads to necessity of intubation and mechanical ventilation support. Complications may be severe as Ventilator-Induced Lung Injury (VILI) and respiratory infections. Weaning process from mechanical ventilation is based on respiratory work reduction and mechanical support to allow patient's respiratory ability to recovery. Respiratory muscle strength give an important contribute. Ultrasound diaphragmatic evaluation is essential to evaluate patients respiratory capacity as diaphragm atrophy usually suggest a difficult process and weaning failure. COVID-19 pneumonia represent a particular type of ARDS (acute respiratory distress syndrome), in which different mechanism such as interstitial edema and diffuse alveolar damage, ventilation-perfusion mismatch, intrapulmonary shunt play a role/attend The aim of this study is to assess diaphragmatic function in weaning from mechanical ventilation in patients affected from COVID-19 respiratory failure and his implications.
Study Type
OBSERVATIONAL
Enrollment
38
Lung ultrasound is performed during mechanical ventilation weaning. The diaphragmatic thickening fraction is evaluated positioning a linear probe in midaxillary line. Inspiratory and expiratory measurements are bilateral and are M-mode images. Right diaphragmatic thickening fraction has been considered as true and reproducible measurement.
Anesthesiology and Intensive Care Clinic - Department of Medicine - ASUIUD
Udine, Italy
Diaphragmatic function evaluation by measuring right diaphragmatic thickening fraction
Right diaphragmatic thickening fraction is evaluated by positioning a linear ultrasound probe at the level of the midaxillary line (pointer oriented towards the axillary cavity). Patient is in the supine position. Inspiratory and expiratory measurements are made as M-mode images. Right diaphragmatic measurement is considered as a reference. .
Time frame: During weaning by mechanical ventilation before attempt of extubation
Weaning attempt success/failure frequency with consequent need of tracheostomy or endotracheal re-intubation.
After extubation it is considered as weaning attempt success a 48 hours time free need of non invasive (not prophylatic) or invasive ventilation with re-intubation and/or tracheostomy
Time frame: After weaning and eventually extubation
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.