Midwall septal fibrosis (MSF) is a common structural abnormality in non-ischaemic dilated cardiomyopathy (DCM). Its presence is believed to increase the risk of malignant ventricular arrhythmias (VA), but the mechanism of arrhythmogenicity is not known. This is particularly relevant in DCM patients with MSF and mid-range left ventricular ejection fraction (LVEF) as they do not currently fulfil criteria for a primary prevention implantable cardioverter-defibrillator (ICD) insertion. Access to the epicardium for electrical measurements of the heart can enhance the understanding of arrhythmogenicity in DCM, however direct epicardial access is invasive. Instead, the investigators will non-invasively combine high resolution 256-lead ECG imaging (ECGI) and latest generation cardiovascular magnetic resonance (CMR) to study the hearts of 60 DCM patients with and without MSF regardless of LVEF, and 60 matched healthy volunteers. The investigators recently invented the re-usable and CMR-safe SMART-ECGI vest technology for this purpose. Using supercomputers, the investigators will fuse the collected ECGI/CMR data and run electromechanical simulations of whole-heart activation to non-invasively measure each participant's personalised risk of malignant VA induction. By panoramically mapping the DCM heart in a single beat, the investigators aim to elucidate how MSF perturbs the cardiac activation front and how this could lead to life-threatening VA. This has the potential to change the method by which cardiologists risk stratify patients with DCM.
Study Type
OBSERVATIONAL
Enrollment
120
ECG imaging acquisition
Cardiac MRI scan
Royal Free Hospital NHS Trust (RFH)
London, United Kingdom
RECRUITINGThe relationship between the electrical and structural substrate in DCM
The investigators will describe the relationship between the electrical and structural substrate in DCM across the spectrum of left ventricular dysfunction.
Time frame: 2 years
Comparison of epicardial activation and conduction patterns via ECGI
The investigators will compare participants with MSF+DCM, MSF-DCM and controls in terms of epicardial activation and conduction patterns (via ECGI).
Time frame: 2 years
Comparison of MSF+DCM, MSF-DCM and controls' electromechanical function of the heart via modelling
The investigators will compare MSF+DCM, MSF-DCM and controls in terms of Electromechanical function of the heart (via 4-dimensional computational models)
Time frame: 2 years
Personalised simulation of risk of malignant ventricular arrhythmia
Applying and exploring simulation methodology to establish predictions for likely propensity to malignant VA (personalised simulations of risk) between MSF+DCM, MSF-DCM and controls groups
Time frame: 2 years
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.