IRMaGe is a Joint Service Unit (UMS) which provides users of brain exploration equipment (clinical MRI and preclinical, TMS, EEG, NIRS and metabolomics). The methods available on this equipment are intended to evolve according to the most recent discoveries and this protocol aims to frame the developments necessary around clinical MRI for IRMaGe can continue to offer tools at the cutting edge of technology.
The studies will be carried out on healthy subjects and voluntary patients, who will have given their consent. Their main objective will be the development and optimization of sequence parameters or design stimulation paradigms in order to optimize the quality and relevance of the images produced taking into account the parameters anatomical, functional or metabolic while respecting the experimental constraints imposed by the protocol concerned (equipment of experimentation, additional physiological measurements, etc.). The main judgement criteria will be measurements inherent in the MRI sequence and a physiological measurement associated in the protocol concerned
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
OTHER
Masking
NONE
Enrollment
600
Eye-tracker Eyelink (eye movements) BIOPAC : (electrodermal resistance) INVIVO Precess : breathing, arterial pressure, pulse, * NIRS Oxymon artinis medical system * tES (transcranial electrical stimulation, Neuroelectrics)
Unité Mixte de Service IRMaGe US 017
La Tronche, France
RECRUITINGDiffusion Tensor Imaging Images
DTi sequences on IRM Achieva 3.0T dStream Philips
Time frame: 1 to 3 hours
BOLD Signal
EPI sequences during cognitive protocol on IRM Achieva 3.0T dStream Philips
Time frame: 1 to 3 Hours
Anatomical Images
Anatomical MR sequences on IRM Achieva 3.0T dStream Philips
Time frame: 1 to 3 hours
Eye movements
Acquired by using eye-tracker (Eye-tracker Eyelink) breathing arteries pressure electrodermal conductance
Time frame: During MRI session
Electrodermal resistance
Acquired on BIOPAC device allowing physiological measurements
Time frame: During MRI session
Blood Pressure/pulse/Breathing
Acquired on INVIVO Precess
Time frame: During MRI session
Near-infrared spectroscopy (NIRS) : Hb OHb concentration measurement
Acquired with NIRS Oxymon artinis medical system
Time frame: During MRI session
tES
Transcranial Electrical stimulation, Neuroelectrics
Time frame: During MRI session