Our study is about to follow adult congenital patients, known with systemic right ventricle (mostly correct transposition of the great arteries ou congenitally corrected transposition fo the great arteries) and systemic valve severe regurgitation which was treated with a Mitraclip device on this tricuspid valve. It's an observationnal study with a 2 years follow up with clinical (symptoms, complications, VO2 exercice test) echographic and MRI outcomes .
Patients with systemic right ventricle (mostly congenitally-corrected transposition of the great arteries or transposition of the great arteries corrected by atrial switch) commonly develop significant systemic tricuspid valve regurgitation which is a therapeutic dilemma for the care team. Surgery (valvuloplasty or replacement) is the common and historical treatment but the rate of mortality is high and results about long-term benefit are contradicting. Percutaneous edge to edge repair could be a alternative to surgery. 10 high-risk surgical patients with severe systemic tricuspid regurgitation undergoing a percutaneous repair were included between January 2019 and November 2022. Our study is a retrospective analysis of short and mid-term clinical, biological, echocardiographic and MRI/TDM outcomes with an expected minimum follow-up of 2 years.
Study Type
OBSERVATIONAL
Enrollment
10
Edge to edge repair of severe tricuspid regurgitation on a right systemic ventricle with a Mitraclip device.
Bordeaux University Hospital
Bordeaux, France
RECRUITINGClinical, VO2 max testing, biological, echocardiographic, cross-sectionnal Imaging data.
Clinical data : dyspnea (NYHA 1/2/3/4), heart palpitations (yes/no), heart failure in the 6 previous months (yes/no)
Time frame: 2 years
VO2 max testing data.
VO2 max testing: VO2 max (ml/min/kg), strenght in watts
Time frame: 2 years
Biological data.
Biological data : hemoglobine (g/dL), hematocrit (%), creatinine (µmol/L), BNP/nt-proBNP (ng/mL) at baseline, 6, 12, 24 months
Time frame: 2 years
Echographic data.
Echocardiographic data : tricuspid insuffisency severity (régurgitant orifice area in mm²), régurgitant volume (mL)), tricuspid annular diameter (cm), and right ventricle systemic function (S'VD in cm/s, TAPSE in mm, shortening right ventricle fraction in %), and area (end-diastolic and end-systolic area) at baseline, 6, 12, 24 months
Time frame: 2 years
Cross-sectionnal Imaging data.
Cross-sectionnal imaging data : quantitative parameters of tricuspid regurgitation (regurgitant volume in mL, percentage of regurgitation in %) and right ventricle systemic function (ejection fraction in %) and volume (end-diastolic and end-systolic volume in mL) at baseline and 6 months.
Time frame: 2 years