This is a monocentric retrospective, open-label clinical study in patients after unilateral or bilateral implantation of hydrophobic acrylic monofocal toric intraocular lens PODEYE TORIC and executed only with standard of care examinations. The investigational device is CE approved. The investigational device and all study products, including the devices used for the study examinations, have been used within the intended use specifications from the manufacturer. In addition, there were no invasive or other burdening examinations. The investigator is an accredited and experienced cataract surgeon and researcher. The primary endpoint is to determine rotational stability in a minimum of 120 eyes of patients with PODEYE TORIC IOL implantation after cataract surgery. Patients will be enrolled for the documentation and evaluation of retrospective data up to 6 months postoperatively.
Age-related changes of the proteins in the crystalline lens lead to cataract formation. Cataracts are a common condition in adults over 40 years of age, and surgical replacement of the cataractous lens with an intraocular lens (IOL) remains an effective way to restore vision to cataract patients. On patients with a low amount of pre-existing corneal astigmatism (defect in the sphericity of the cornea with a focal point depending on the meridian), the implantation of a spherical monofocal IOL is the state- of- the-art when targeting a good correction of distance visual function. However, in case of pre-existing corneal astigmatism, the implantation of spherical IOLs might not be the best solution, as such lenses only correct for spherical errors and leave the astigmatism uncorrected. Toric IOLs are obtained by adding a cylinder power to the basis optic of a given spherical power, thus correcting for both spherical and cylindrical refractive errors. Toric IOLs provide the opportunity to reduce or eliminate astigmatism, thus offering patients with pre-existing astigmatism the possibility of restoring their distance vision with reduced or no need for the use of spectacles or contact lenses with a cylindrical correction. Not correcting the astigmatism component at the time of cataract surgery is an important cause for not obtaining planned emmetropia following IOL implantation. A previous study found that more than 22% of patients undergoing cataract surgery have substantial corneal astigmatism superior than 1.25 D and would benefit from toric IOL implantation 1). This study will add to the knowledge on toric IOLs and help improve the care of patients and the outcomes of cataract surgery after toric IOL implantation. The study is a monocentric, retrospective study to investigate rotational stability and visual performance after mono- or bilateral implantation of PODEYE TORIC intraocular lens following cataract surgery, executed only with standard of care examinations. The study outcomes will be used to confirm the safety performance for a stable IOL positioning of the investigation al device. Preoperative, surgical and postoperative data (up to 6 months after surgery) will be collected retrospectively by reviewing the patient charts. The investigational device PODEYE TORIC IOL is CE approved and commercially available in the country where this clinical investigation is being carried out. The investigational device and all study products, including the devices used for the study examinations, have been used within the intended use specifications from the manufacturer. In addition, no invasive or other burdening examinations will occur for the patient.
Study Type
OBSERVATIONAL
Enrollment
105
Patients will be contacted consecutively and will be enrolled after the patient informed leaflet has been given to them and after obtaining their consent to the scientific use of their data collected retrospectively (preoperative, surgery, postoperative routine visits). Patients will only be enrolled after the routine 4-6 months visit has been performed.
Clinique Beau Soleil
Montpellier, France
Rotational Stability
Rotational stability is an important parameter on toric IOLs, as postoperative IO L rotation can lead to inappropriate correction of corneal astig matism and decrease in uncorrected distance visual acuity. The primary study endpoint is the absolute value of rotation between the day of surgery and the postoperative visit 6 months after surgery. The absolute value of rotation should be less than 10° in 90% of the eyes implanted with POD EYE TORIC lens according to safety declarations of EN ISO 11979-7:2018.
Time frame: 6 months
Stability of Manifest Refraction (Spherical Equivalent)
Manifest refraction will be assessed using the spherical equivalent: Manifest refraction Spherical Equivalent (MRSE). Negative cylinder notation will be used. MRSE is calculated by the following formula: MRSE = sphere + 1/2 cylinder. Descriptive analysis of sphere, cylinder and MRS E will be reported. Stability of the MRSE will be assessed by summarizing the change in MRSE between adjacent visits ( mean, standard deviation, minimum and maximum, and 95% confidence interval).
Time frame: 6 months