To compare the quantitative and qualitative optical outcomes between single-step transepithelial photorefractive keratectomy (TransPRK) and off-flap epipolis laser in situ keratomileusis (Epi-LASIK) in moderate to high myopia.we included patients with moderate to high myopia who were randomized to have TransPRK in one eye and Epi-LASIK in the other eye. All patients underwent comprehensive ophthalmological examinations, including uncorrected (UDVA) and corrected distance visual acuities (CDVA), manifest refraction, intraocular pressure, anterior and posterior segment examination, corneal topography measured by Scheimpflug scanning-slit topographer (Pentacam, Oculus Optikgerate GmbH), contrast sensitivity (CS) under photopic and mesopic conditions (CSV-1000E, Vector Vision Inc., Greenville, OH, USA) with correction by spectacles, ocular wavefront aberrometry (OPD-Scan II, Nidek Co. Ltd). At each follow-up, CS and aberration measures were repeated 3 times and the average value was analyzed. Optical parameters were repeated 1, 3, 6, and 12 months after surgery.Statistical analysis was performed using SPSS software (version 22.0, SPSS, Chicago, Inc.). Kolmogorov-Smirnov test was used to check the normal distribution of variables. Student t-test or Wilcoxon rank sum test was used based on the normality of data. A P value less than 0.05 was considered statistically significant.
Study Type
OBSERVATIONAL
Enrollment
38
aberrations
ocular high-order aberrations including spherical, coma and trefoil aberrations were measured by OPD-Scan II
Time frame: 2016.03.01-2018.06.05
contrast sensitivity
contrast sensitivity and contrast sensitivity under glare condition measurements were performed by the CSV-1000E which could test four spatial frequencies: 3,6,12 and 18 cycles/degree (cpd) at 2.5m. The contrast sensitivity was measured under photopic (596.7cd/㎡) and scotopic (0.01cd/㎡) conditions and the contrast sensitivity under glare condition was taken under scotopic condition with glare
Time frame: 2016.03.01-2018.06.05
haze
Corneal haze grade was recorded according to Fantes's report: 0, no haze; 0.5, trace haze only could be seen by oblique illumination; 1,more visible haze not interfering with the visibility of iris details; 2, mild influence of iris details; 3, moderate influence of iris details; 4, marked haze obscuring the stroma of ablation area.
Time frame: 2016.03.01-2018.06.05
postoperative pain
Subjective pain scores were evaluated on the third day according to a predetermined scale ranging from 0 to 5 as follows: 0, no pain or discomfort; 1, photophobia and tears; 2, photophobia and tears with mild pain; 3, photophobia and tears with moderate pain that does not require oral medication; 4, photophobia and tears with severe pain that oral medication can relieve; 5, photophobia and tears with severe pain that oral medication cannot relieve.
Time frame: 2016.03.01-2018.06.05