Capnodynamic monitoring has the potential to offer continuous and non-invasive measurements of heart and lung function in patients requiring ventilation in an intensive care setting. Since mechanical ventilation with full patient synchronization is commonly used in ICU, capnodynamic monitoring can be immediately embedded in clinical care and compared to current methods of monitoring cardiac output, lung volumes and oxygen delivery. This observational study will explore capnodynamic monitoring in mechanically ventilated patients with a range of cardiorespiratory compromise.
This study aims to: 1. compare the estimation of cardiac output (CO) using the capnodynamic method (COEPBF) with contemporary reference methods; 2. compare the estimation of mixed venous oxygen saturation (SmvO2) with invasively obtained blood gas analyses; 3. generate observational data on end-expiratory lung volume (EELV) when ventilator settings, and in particular PEEP, are changed; 4. combine 1-3 to provide a physiological construct of cardiorespiratory function
Study Type
OBSERVATIONAL
Enrollment
100
In patients fully synchronized with mechanical ventilation, the capnodynamic method calculates the effective pulmonary blood flow, the end-expiratory lung volume and estimates the mixed venous oxygen saturation. The capnodynamic method uses short inspiratory or expiratory pauses to induce small changes in CO2 concentration the enable the mole balance to be resolved for the capnodynamic equation: ELV x \[(FACO2(n)-FACO2(n-1)\] = delta(n) x EPBF \[CvCO2(n)\] - VTCO2.
Intensive Care Unit, Liverpool Hospital, South Western Sydney Local Health District
Liverpool, New South Wales, Australia
RECRUITINGCorrelation between capnodynamic effective pulmonary blood flow and cardiac output measured by pulmonary artery thermodilution or echocardiography
Capnodynamic measurements of effective pulmonary blood flow are compared with contemporaneously obtained cardiac output measurements using clinical reference methods
Time frame: Through study completion, an average of 1 year
Correlation between capnodynamic estimates of mixed venous oxygen saturation and blood gas analysis of blood obtained from the pulmonary artery pulmonary.
Capnodynamic estimates of mixed venous oxygen saturation are compared with contemporaneously obtained blood gases from the pulmonary artery catheter
Time frame: Through study completion, an average of 1 year
Prediction by capnodynamic monitoring of combined changes in end expiratory lung volume and effective pulmonary blood flow to assess changes in pulmonary gas exchange during various levels of PEEP
At three different levels of PEEP, the interactions between end expiratory lung volume and effective pulmonary blood flow will be assessed and correlated to changes in arterial partial pressure of oxygen and carbon dioxide
Time frame: Through study completion, an average of 1 year