The post-stroke survivors suffered from shoulder pain are very common. The investigators performed Fu's subcutaneous needling (FSN). This experiment used a randomized controlled trial to assess the immediate, short-term and long-term effects of Fu's subcutaneous needling therapy on hemiplegic shoulder pain in patient with stroke.
The prevalence of complication in post-stroke survivors is 30-96%. Post-stroke pain is the most common complication. According to previous researches there are sixty percent post-stroke survivors who suffered from upper limb pain. The mechanism causes post-stroke shoulder pain is imbalance of shoulder muscles and in-coordination of shoulder motor control due to cerebral vascular disease. Post-stroke shoulder pain often causes the limitation of shoulder range of motion, and the pain always affected quality of life and daily activities. Because of shoulder pain, those post-stroke survivors postponed the program of rehabilitation. The treatments of post-stroke shoulder pain are transcutaneous electrical nerve stimulation, drug, intra-articular injection and nerve block. Acupuncture with combination of rehabilitation has been proved by many researches in alleviating pain and increasing quality of life in treating post-stroke shoulder pain. Fu's subcutaneous needling is a newly technique based on meridian theory and the technique is used to treat cervical, lumbar and four limb's pain proved by many researches. Fu's subcutaneous needling in managing post-stroke pain has less reported, so investigator set up a proposal to see if the Fu's subcutaneous needling could elevate more therapeutic effect compared to usual care or not. The investigators will enroll patients into two groups, experimental and control groups. The interventions in experimental group are Fu's subcutaneous needling in combination with rehabilitation, and in control group is rehabilitation. The trial will extend two weeks, and investigator will treat with Fu's subcutaneous needling three times in the first, second and fourth day when the patients include to our trial. The outcome measurements are visual analog scale, range of motion of shoulder, pressure pain threshold of myofascial trigger point, acromion-greater tuberosity distance, Fugl-Meyer assessment in upper extremity and functional independence measure.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
48
physician will use a disposable Fu's subcutaneous needling (FSN) to penetrate the subject's skin in the middle from elbow lateral epicondyle to radial styloid process. Then physician will push forward the needle parallel to the skin surface. the physician will sway the needle 100 times in a minute. After procedure of swaying needle, the physician will instruct subject to do several movements, and each movement will perform 10 seconds and rest 10 seconds for 3 repetitions. The movements are active isometric elbow flexion, active isometric shoulder internal rotation, passive shoulder external and internal rotation. After above re-perfusion approach of muscles, the physician will take out the needle to finish the treatment.
Rehabilitation mentioned here is the regular rehabilitation programs for treating post-stroke hemiplegic shoulder pain prescribed by the rehabilitation physician.
China Medical University Hospital
Taichung, Taiwan
Visual Analog Scale
A Visual Analog Scale consists of a line, often 10 cm long, with verbal anchors at either end, on left of line, zero, meant no pain otherwise on right, 10, meant strong pain. The patient places a mark at a point on the line corresponding to the patient's rating of pain intensity.
Time frame: 1 day
Pressure Pain Threshold
Pressure pain threshold (PPT) is defined as the minimum force applied which induces pain. This measure has proven to be commonly useful in evaluating tenderness symptom
Time frame: 1 day
Range of Motion of Shoulder
Range of Motion is the measurement of movement around a specific joint, measured in degrees of a circle. In this study we measure shoulder joint, glenohumeral joint, in flexion, extension, external and internal rotation.
Time frame: 1 day
Acromion-GreaterTuberosity Distance
In this study we assess of shoulder joint subluxation by means of ultrasound measurement of Acromion-greater tuberosity distance.
Time frame: 1 day
Fugl-Meyer assessment in upper extremity
The Fugl-Meyer Assessment (FMA) is a stroke-specific, performance-based impairment index. In upper extremity, we measure motor function included shoulder, elbow, wrist and hand, and assess coordination using finger to nose.
Time frame: 1 day
Functional Independence Measure
The Functional Independence Measure (FIM) is an instrument that was developed as a measure of disability. Includes measures of independence for self-care, including sphincter control, transfers, locomotion, communication, and social cognition.
Time frame: 1 day
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.