In the international literature there are only few publication about the normal biomechanical parameters of the lower limb examined prospectively in healthy population. The goal of our study to determine 15 anatomical and biomechanical parameters of the lower limb using 3D reconstruction based on upright, stereo radiographs in young, healthy volunteers.
Study Type
OBSERVATIONAL
Enrollment
100
EOS Micro Dose imaging will be done. SterEOS 3D recontruction of the lower limb and pelvis will be performed.
Ádám Schlégl
Pécs, Baranya, Hungary
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Length of the femoral mechanical axis (femur length) - mm
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters, including: • Length of the tibial mechanical axis (tibia length) - mm
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • The length of the lower limb (limb length) - mm
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Femoral head diameter - mm
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Neck length (the distance between the centre of the femoral head and the proximal diaphyseal axis, when following the axis of the femoral neck) - mm
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Neck shaft angle, aka the collodiaphyseal angle (CD angle, the angle between the femoral neck axis and the proximal diaphysis axis) - degrees
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Femoral offset (the distance between the centre of the femoral head and the closest point of the femoral shaft axis) - mm
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Mechanical tibiofemoral angle (mTFA, the angle between the mechanical axis of the femur (which passes from the femoral head through the centre of the distal femur) and the mechanical axis of the tibia (from the centre of the proximal tibia to the middle of the ankle) in the frontal plane of knee (convention dictates that in the varus position angles are negative, and in valgus positive) - degrees
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Sagittal tibiofemoral angle (sTFA, the angle between the femural and tibial mechanical axis in the sagittal plane) - degrees
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Femoral mechanical axis-femoral shaft angle (FM-FS, the angle between the mechanical and anatomical axis of the femur in the frontal plane of the knee) - degrees
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Femur mechanical angle (FMA, the angle between the femoral mechanical axis and the tangent of the femoral condyles medially) - degrees
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Tibial mechanical angle (TMA, the angle between tibial mechanical axis and the tangent of the tibia plateau medially) - degrees
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Femoral torsion (the angle between the femoral neck axis and the posterior condylar line projected on a plane perpendicular to the mechanical axis of the femur) - degrees
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Tibial torsion (the angle between the transmalleolar and transcondylar axis projected on a plane perpendicular to the mechanical axis of the tibia) - degrees
Time frame: 6 months
3D reconstruction with 15 anatomical and biomechanical parameter of the lower limb
Based on the stereo radiographs, SterEOS 3D reconstruction will be done. The SterEOS software calculates automatically 15 parameters including: • Femorotibial rotation (the angle between the posterior condylar line of the femur and tibia) - degrees
Time frame: 6 months