QARIN 1 is a study of \[18F\]DPA-714 Translocation Protein (TSPO) Positron Emission Tomography (PET) for longitudinal, quantitative assessment of brain neuroinflammation following whole brain radiation therapy. This TSPO PET, uses a radioactive tracer. An optional MRI (magnetic resonance imaging) will also be performed to monitor brain microstructure damages induced by neuroinflammation. Primary Objectives * Assessment of temporal and regional variability of uptake of translocator protein (TSPO) positron emission tomography (PET) tracer. * Regional variability will be assessed in medial temporal lobe, frontal lobe, and in white matter * Temporal variability will be assessed by scanning each subject four-times: at baseline (before or within 2 weeks of start of radiation therapy), before start of chemotherapy, at 1 year from the initiation of the radiation therapy, and at 1.5-2 years from the initiation of the radiation therapy * Correlation of radiation dose in specific brain regions with radiation induced neuroinflammation as measured by uptake of TSPO PET tracer. Exploratory Objectives * Assessment of radiation-induced brain microstructure injuries (RIBMI) in specific brain regions (medial temporal lobe, frontal lobe, and in white matter) using advanced magnetic resonance imaging (MRI) techniques. * Association of radiation dose with MRI measures of RIBMI in these specific brain regions. * Association of PET measures of RIN with MRI measures of RIBMI. * Association of PET measure of RIN and MRI measures of RIBMI in specific regions of interest (ROI) with specific domain of neuro-cognition. For example, to investigate whether PET measure of RIN and MRI measures of RIBMI in hippocampal ROI have strongest association with episodic memory; whether frontal lobe cortical ROI are associated with attention and executive function. * Association of a novel MRI based technique for assessment of RIN with TSPO PET. * Association of the PET and MRI measure of neuroinflammation within 2- years of completion of radiation with delayed cognitive outcome that will be measured at 3, 4 and 5 years from the completion of radiation
The participant will have 4 PET scans using a novel PET tracer that will help the investigators to quantify when and where in brain neuroinflammation happens following radiation therapy. The participant will receive the first PET scan either before your first dose of radiation therapy or within 2 weeks of the start of radiation therapy. The second PET scan will be obtained before starting chemotherapy. The third scan will be after 1 year of treatment.The final scan will be 1 and a half to 2 years after the start of treatment.The scan process will begin an hour or so after the participant has been given tracer by injection. The entire PET scan process lasts about 2 hours.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
22
Intravenous injection * Before or within 2 weeks of starting radiation therapy * Before starting chemotherapy * 1 year after the start of radiation therapy Timing cont. * 1.5 to 2 years after the start of radiation therapy
St.Jude Children's Research Hospital
Memphis, Tennessee, United States
SUVr
SUVr values for dorsolateral prefrontal cortex comparing baseline vs. follow up 1
Time frame: follow up 1: up to 13 weeks after radiation therapy
SUVr
SUVr values for medial prefrontal cortex comparing baseline vs. follow up 1
Time frame: follow up 1 : up to 13 weeks after radiation therapy
SUVr
SUVr values for hippocampus comparing baseline vs. follow up 1.
Time frame: follow up 1 : up to 13 weeks after radiation therapy
SUVr
SUVr values for Corpus callosum comparing baseline vs. follow up 1.
Time frame: follow up 1 : up to 13 weeks after radiation therapy
SUVr
SUVr values for corticospinal tract comparing baseline vs. follow up 1.
Time frame: follow up 1 : up to 13 weeks after radiation therapy
SUVr
SUVr values for superior longitudinal fasciculus comparing baseline vs. follow up 1
Time frame: follow up 1 : up to 13 weeks after radiation therapy
SUVr
SUVr values for dorsolateral prefrontal cortex comparing baseline vs. follow up 2.
Time frame: follow up 2: up to 53 weeks after radiation therapy
SUVr
SUVr values for medial prefrontal cortex comparing baseline vs. follow up 2.
Time frame: follow up 2: up to 53 weeks after radiation therapy
SUVr
SUVr values for hippocampus comparing baseline vs. follow up 2.
Time frame: follow up 2: up to 53 weeks after radiation therapy
SUVr
SUVr values for Corpus callosum comparing baseline vs. follow up 2.
Time frame: follow up 2: up to 53 weeks after radiation therapy
SUVr
SUVr values for corticospinal tract comparing baseline vs. follow up 2.
Time frame: follow up 2: up to 53 weeks after radiation therapy
SUVr
SUVr values for superior longitudinal fasciculus comparing baseline vs. follow up 2.
Time frame: follow up 2: up to 53 weeks after radiation therapy
SUVr
SUVr values for dorsolateral prefrontal cortex comparing baseline vs. follow up 3.
Time frame: follow up 3: up to 2 years after radiation therapy
SUVr
SUVr values for medial prefrontal cortex comparing baseline vs. follow up 3.
Time frame: follow up 3: up to 2 years after radiation therapy
SUVr
SUVr values for hippocampus comparing baseline vs. follow up 3.
Time frame: follow up 3: up to 2 years after radiation therapy
SUVr
SUVr values for Corpus callosum comparing baseline vs. follow up 3
Time frame: follow up 3: up to 2 years after radiation therapy
SUVr
SUVr values for corticospinal tract comparing baseline vs. follow up 3.
Time frame: follow up 3: up to 2 years after radiation therapy
SUVr
SUVr values for superior longitudinal fasciculus comparing baseline vs. follow up 3.
Time frame: follow up 3: up to 2 years after radiation therapy
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.