This is a randomized controlled trial to investigate the effect of capsular tension ring (CTR) implantation on intraocular lens (IOL) tilt and decentration in cataract patients with high myopia.
Exact positioning and alignment of the IOL with the visual axis are the prerequisites of high-quality visual performance after cataract surgery. A certain degree of IOL tilt and decentration occur after uneventful cataract surgery, most of which are clinically tolerant. However, the relatively large capsular bag volume, zonular weakness, and vitreous liquefaction in cataract patients with high myopia may increase the IOL position instability, such as tilt, decentration and even dislocation, leading to the deterioration of visual function. Thus, how to improve the long-term stability of IOL position in high myopic cataract patients is an urgent issue to be addressed. Previous studies have shown that CTR implantation during cataract surgery can increase the IOL stability in patients with normal axial length; however, its impact on IOL position of cataract patients with high myopia remains unclear. In this randomized clinical trial, patients who meet the inclusion criteria will be divided into three layers according to the axial length: (1)26mm≤AL\<28mm (2)28mm≤AL\<30mm (3)AL≥30mm We are going to recruit 186 patients in total, with 62 patients in each layer. Patients on each layer will be randomly divided into experimental group (CTR implantation) and control group (only IOL implantation). If both eyes of a patient meet the inclusion criteria, only the first operated eye is included in the statistics analysis. All included patients will be followed up at 1 week, 1 month, 3 months, 6 months, and 1 year postoperatively. Visual acuity, IOL tilt, IOL decentration, posterior capsule attachment with IOL, anterior capsule contraction, posterior capsular opacification, and visual quality will be measured and compared between the experimental group and the control group at different timepoints.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
186
Device: CTR (276001G; OPHTEC BV, Netherlands) Device: IOL (920H; Rayner Intracular Lenses Limited,Hove,East Sussex,UK) All patients undergo uneventful phacoemulsification by a 3.0 mm temporal transparent corneal incision using Centurion Vision System (Alcon Laboratories, Fort Worth, TX, USA). After the nucleus and cortex are removed, a capsular tension ring is implanted in the capsular bag and then IOL is implanted.
Device: IOL (920H; Rayner Intracular Lenses Limited,Hove,East Sussex,UK) All patients undergo uneventful phacoemulsification by a 3.0 mm temporal transparent corneal incision using Centurion Vision System (Alcon Laboratories, Fort Worth, TX, USA). After the nucleus and cortex are removed, IOL is implanted in the capsular bag.
Zhongshan Ophthalmic Center, Sun Yat-sen University
Guangzhou, Guangdong, China
RECRUITINGIOL dencentration
Measured by anterior segment OCT (CASIA2)
Time frame: 3 months after surgery
IOL dencentration
Measured by anterior segment OCT (CASIA2)
Time frame: Baseline (before surgery), 1 week, 1 month, 6 months, 1 year after surgery
IOL tilt
Measured by anterior segment OCT (CASIA2)
Time frame: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year after surgery
Anterior capsule contraction
Compare the area of anterior capsule opening recorded by slit lamp photograph and analyzed by Image J software.
Time frame: Baseline, 1 week, 1 month, 3 months, 6 months, 1 year after surgery
Posterior capsule attachment with IOL
Measured by anterior segment OCT (CASIA2) and analyzed by Image J software.
Time frame: 1 week, 1 month, 3 months, 6 months, 1 year after surgery
Posterior capsular opacification
Recorded by slit lamp photograph and analyzed by EPCO2000 analysis software.
Time frame: 1 week, 1 month, 3 months, 6 months, 1 year after surgery
BCVA
BCVA is evaluated with ETDRS visual acuity chart.
Time frame: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year after surgery
Optical quality
Measured by OPD-SCAN III.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: Baseline (before surgery), 1 week, 1 month, 3 months, 6 months, 1 year after surgery
Visual function
Measured by visual function assessment questionnaires.
Time frame: 3 months, 6 months, 1 year after surgery