The purpose of this randomized controlled trial is to assess and compare radiographic and clinical outcomes in patients who are to undergo combined interbody/posterolateral lumbar fusion procedures, supplemented with pedicle screw instrumentation, using one of the following interbody cages; the Medtronic Adaptix™ cage with roughened micro and nano-textured titanium surfaces or the CAPSTONE® poly-ether-ether-ketone cage.
The randomized controlled trial will prospectively evaluate the efficacy of Medtronic Adaptix™ titanium implants supplemented with a pedicle screw system as compared to a Medtronic CAPSTONE® PEEK cage currently used in routine fashion for lumbar interbody fusion procedures. This study will capture clinical and radiographic outcomes on patients up to 2 years postoperatively. Both cages will be used in conjunction with a 50:50 mixture of autograft: allograft using milled local autograft bone and GRAFTON™ DBM DBF (no iliac crest autograft will be utilized). This single-centered study will enroll up to 100 subjects, with subjects followed for 24 months post-surgery. All subjects enrolled in the study will be recruited from a pool of subjects eligible for combined interbody/posterolateral lumbar fusion surgery. The inclusion/exclusion criteria are listed below.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
100
Patients who will be having a spinal fusion procedure as part of their standard of care treatment will be randomized to receive either the Medtronic titanium or the PEEK cage supplemented with a pedicle screw system and milled local autograft bone supplemented with GRAFTON DBM DBF. In order to assess fusion, patients will undergo a research-only CT Scan at 6 months post-surgery.
Medtronic CAPSTONE® PEEK cage
The Ohio State University Wexner Medical Center Neurological Surgery
Columbus, Ohio, United States
Fusion rate at 6 months
A subject will be considered a success if fusion is a Grade BSF-3 at 6 months. The primary outcome measure of effectiveness will be determined by the fusion rate at 6 months post-operatively in subjects implanted with either titanium cage as compared to the PEEK cage.
Time frame: 6 months
Timing of fusion
Secondary measures of effectiveness will be determined by the principal investigator by evidence and timing of fusion observed in X-rays post-operatively (3, 6, 12, and 24 months).
Time frame: 24 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.