The proposed study evaluates the effect of carbon fiber brace design on forces across the ankle. Research suggests that ankle arthritis develops following ankle fracture due, in part, to elevated forces on the cartilage. It is expected that carbon fiber braces can reduce forces in the ankle joint thereby reducing the risk of developing arthritis following injury. In this study, carbon fiber braces will be tested to determine how they influence the forces acting on the ankle cartilage. The proposed study will provide evidence that can be used by clinicians and researchers to design carbon fiber braces to effectively reduce forces on ankle cartilage.
The primary purpose of this line of research is to investigate the effects of carbon fiber custom dynamic orthosis (CDO) use on forces and contact stress at the ankle, with the goal of reducing the development of post traumatic osteoarthritis (PTOA). Research suggests that PTO develops, in part, due to increased ankle contact stress following fracture. It is expected that reducing articular contact stress has the potential to delay or prevent PTOA development. CDOs have been shown to significantly improve function after extremity injury, and show promise for offloading the injured ankle joint after severe lower extremity injuries. Therefore, the proposed effort is designed to evaluate CDOs effects on forces and articular contact stress at the ankle. Adult participants who have sustained a traumatic ankle fracture of the tibial pilon will be evaluated while wearing two CDOs, with a primary dependent measure of ankle joint contact stress. Following consent and enrollment weight bearing computerized tomography (CT) images will be collected and used to determine the geometry of the joint, and the articular contact stress using discrete element analysis. Participants will be cast and fit for two CDOs. Participants will be blinded to the design variation of each device and will only know them as CDO-A or CDO-B. Testing will be completed under 3 conditions: No-CDO, CDO-A, CDO-B, with each bracing condition (A/B) representing a different CDO. Physical performance measures will incorporate tests of agility, speed, and lower limb power to ensure that the CDOs do not negatively affect physical function. Questionnaires will be used to evaluate participants' current and desired activity level, pain with and without using a CDO, satisfaction with the study CDOs, perception of comfort and smoothness between CDOs, and preference between CDOs. Semi-structured interviews will be completed to fully capture the participant's perspective with each study CDO. Lower limb forces and motion will be assessed using a computerized motion capture system and force plates embedded in the floor. Forces between the foot and CDO footplate will be measured using force sensing insoles, and muscle activity data will be collected using wireless surface electromyography sensors. Each CDO will be mechanically tested, and participant demographic and anthropometric data will be recorded.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
SINGLE
The carbon fiber custom dynamic orthosis will consist of a semi-rigid foot plate, a posterior carbon fiber strut, and a proximal cuff below the knee.
University of Iowa
Iowa City, Iowa, United States
Joint Contact Stress Exposure (Model estimated)
Joint contact stress exposure (MPA-s/gait cycle) will be estimated using a participant specific musculoskeletal model.
Time frame: Baseline
Peak Plantar Force (total foot)
Plantar forces (N) will be measured across the forefoot (100% of sensor) as participants walk without a CDO and with each CDO.
Time frame: Baseline
Plantar Force Impulse (total foot)
Plantar force impulse (Ns) across the forefoot (100% of sensor) will be calculated using the integral of the force over the stance phase as participants walk without a CDO and with each CDO.
Time frame: Baseline
Peak Plantar Force (forefoot)
Plantar forces (N) will be measured across the forefoot (distal 40% of sensor) as participants walk without a CDO and with each CDO.
Time frame: Baseline
Plantar Force Impulse (forefoot)
Plantar force impulse (Ns) across the forefoot (distal 40% of sensor) will be calculated using the integral of the force over the stance phase as participants walk without a CDO and with each CDO.
Time frame: Baseline
Peak Plantar Force (midfoot)
Plantar forces (N) will be measured across the forefoot (middle 30% of sensor) as participants walk without a CDO and with each CDO.
Time frame: Baseline
Plantar Force Impulse (midfoot)
Plantar force impulse (Ns) across the forefoot (middle 30% of sensor) will be calculated using the integral of the force over the stance phase as participants walk without a CDO and with each CDO.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: Baseline
Peak Plantar Force (hindfoot)
Plantar forces (N) will be measured across the forefoot (proximal 30% of sensor) as participants walk without a CDO and with each CDO.
Time frame: Baseline
Plantar Force Impulse (hindfoot)
Plantar force impulse (Ns) across the forefoot (proximal 30% of sensor) will be calculated using the integral of the force over the stance phase as participants walk without a CDO and with each CDO.
Time frame: Baseline
Numerical Pain Rating Scale
Pain will be assessed using a standard 11-point numerical pain rating scale, in which 0 = no pain and 10 = worst pain imaginable.
Time frame: Baseline
Participant Device Preference
The participant will rank order their preference for their standard of care device (if applicable), NoCDO, CDO-A, CDO-B on a questionnaire.
Time frame: Baseline
Four Square Step Test (4SST)
The 4SST (s) is a standardized timed test of balance and agility.
Time frame: Baseline
Sit to Stand 5 Times (STS5)
STS5 (s) is a well-established timed measure of lower limb muscle strength and power. Participants are instructed to stand up and sit down 5 times as fast as possible.
Time frame: Baseline
Ankle Range of Motion
Ankle range of motion (degrees) during gait.
Time frame: Baseline
Peak Ankle Moment
Peak ankle moment (Nm/kg) during gait.
Time frame: Baseline
Peak Ankle Power
Peak ankle power (W/kg) during gait.
Time frame: Baseline
The Orthotics Prosthetics Users' Survey (OPUS)
Satisfaction with device will be assessed using the Orthotics Prosthetics Users' Survey Satisfaction With Device Score (11-55). Lower scores indicate a better outcome.
Time frame: Baseline
Modified Socket Comfort Score (Comfort)
Comfort scores range from 0 = most uncomfortable to 10 = most comfortable.
Time frame: Baseline
Modified Socket Comfort Score (Smoothness)
Smoothness scores range from 0 = least smooth to 10 = most smooth.
Time frame: Baseline