In this study is tested the validity of placental vascular indices obtained from placenta ultrasonographic sphere biopsy and entire placenta investigation.
Although, to this date, there have been a number of human placental studies that concerned the evaluation of placental 3 dimensional power Doppler vascularization with the use of VOCAL technique, but there was no one in which placental vasculature has been compared between the sonobiopsy and whole placental volume.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
150
Images that contributed to the determination of placental volume and 3-DPD indices were obtained at the time of visit. All 3-D scans ultrasound measurements were performed by a Voluson 730 Expert ultrasound machine equipped with a multifrequency probe (2-5 MHz) to acquire images. Each sample was examined using 3-D rendering mode, in which the colour and gray value information was processed and combined to supply 3-D image. For laterally located placentas, the investigator positioned the transducer on a slight lateral inclination to obtain proper images. Power Doppler window was placed over the placenta to map the vascular tree from basal to chorionic plates. The 3-D static volume box was placed over the entire placenta volume. The sweep angle was set at maximum 70°. Each image was recovered from the disk in succession for processing. During gestation, the investigator recorded one sample from each patient.
The two-dimensional (2-D) transabdominal conventional study provided data about fetal position, biometry, body movements and fetal heart rate as well as placental localization. The factorial default setting 'Obstetrics' was applied in 2-D mode.
Universitiy of Szeged
Szeged, Hungary
Maternal characteristics (BMI)
The pre-pregnancy body mass index (BMI) registered at the initial visit during prenatal care was calculated as the body weight (kg) per height (m2).
Time frame: through study completion, 2 years
Neonatal outcome 1; based on gestational age
The participants were recorded by gestational age et birth
Time frame: during first day of life
Neonatal outcome 2, based on maturation of neonates
Neonates were investigatied by maturation ( gestational age before 36+6 week) (prematurity
Time frame: during first day of life
Neonatal outcome 3, (birth weight of newborns)
Neonates birth weight calculation (gram)
Time frame: during first day of life
Neonatal outcome 4; Apgar score
Neonates poor adaptation status (Apgar score (\<7) at 5 minutes)
Time frame: during first day of life
Neonatal outcome 5, (umbilical cord pH)
Neonates poor adaptation status (umbilical cord pH \<7.2)
Time frame: during first day of life
Neonatal outcome 6; delivery complication
Delivery complication ( cesarean section due to fetal distress)
Time frame: during first day of life
Neonatal outcome 7, necessary of intensive care unit
Neonates transfer to neonatal intensive care unit (NICU)
Time frame: during first week of life
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
2D ultrasound investigaiotn of gestation (fetal biometry, placentation)
Routine ultrasound examination, based on Guideline of Hungarian Obstetrics and gynecologists (fetal biometry: biparietal diameter, head circumference, abdominal circumference, femur length; investigation of the placenta, place of placentation, Grannum staging)
Time frame: during prenatal care till the labour