This trial is part of a portfolio of studies designed to assess the clinical and operational performance of Abbott's NxTekTM Malaria Pf Plus and NxTekTM Malaria Pf/Pv Plus Rapid Test Devices.
A prospective cross-sectional multi-center diagnostic accuracy trial in intended-use settings of the: 1. NxTekTM Malaria Pf/Pv Plus Rapid Test Device for the qualitative detection histidine-rich protein II (HRP-II antigens) and pLDH of Plasmodium falciparum (P.f) and Plasmodium vivax (P.v) malaria in human whole blood. 2. NxTekTM Malaria Pf PlusRapid Test Device for the qualitative detection of histidine-rich protein II (HRP-II antigens) and pLDH of Plasmodium falciparum (P.f) malaria in human whole blood.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
1,023
NxTekTM Malaria Pf/Pv Plus: A sensitive rapid chromatographic immunoassay for the qualitative detection of histidine-rich protein 2 (HRP2) and Plasmodium lactate dehydrogenase (pLDH) of Plasmodium falciparum(P.f.) on one test line and of pLDH of Plasmodium vivax (P.v.) malaria on a second test line in human whole blood. This test is a lateral flow test for in vitro professional diagnostic use and intended as an aid to early diagnosis of Malaria infection in-patients with clinical symptoms. NxTekTM Malaria Pf Plus: A sensitive rapid chromatographic immunoassay for the qualitative detection of histidine-rich protein 2 (HRP2) and pLDH on a single test line of Plasmodium falciparum(P.f.) malaria in human whole blood. This test is a lateral flow test for in vitro professional diagnostic use and intended as an aid to early diagnosis of Malaria infection in-patients with clinical symptoms.
Medical Parasitology Research Unit, Aklilu Lemma Institute of Pathobiology (ALIPB), Addis Ababa University (AAU).
Addis Ababa, Ethiopia
Assess the sensitivity, specificity, positive and negative predicting values (PPV and NPV) [altogether referred to hereafter as "diagnostic accuracy"] of NxTekTM Malaria Pf Plus
To assess the sensitivity, specificity, positive and negative predicting values (PPV and NPV) \[altogether referred to hereafter as "diagnostic accuracy"\] of NxTekTM Malaria Pf Plus in intended use settings for detecting P.f. infections in capillary whole blood samples collected prospectively from patients with symptoms suggestive of malaria (e.g. febrile).
Time frame: 6 months
To assess the diagnostic accuracy of NxTekTM Malaria Pf/Pv Plus.
To assess the diagnostic accuracy of NxTekTM Malaria Pf/Pv Plus in intended use settings for detecting P.f. and P.v. infections in capillary whole blood samples collected prospectively from patients with symptoms suggestive of malaria (e.g. febrile).
Time frame: 6 months
Estimates of diagnostic accuracy characteristics with 95% confidence intervals of comparator tests (05FK50, 05FK80, 05FK120, LM)
Estimates of diagnostic accuracy characteristics with 95% confidence intervals of comparator tests (05FK50, 05FK80, 05FK120, LM), using the reference test as standard of truth for the detection of P. falciparum and, when relevant, P.v. infections in patients with symptoms suggestive of malaria
Time frame: 6 months
Estimates of diagnostic accuracy characteristics with 95% confidence intervals ofthe index tests for the detection of P.f.infections with hrp2 and/or hrp3 deletions
Estimates of diagnostic accuracy characteristics with 95% confidence intervals of the index tests for the detection of P.f. infections with hrp2 and/or hrp3 deletions in patients with symptoms suggestive of malaria
Time frame: 6 months